- 6 -
28,500(7,182)
17,500(4,410) 11,000(2,772)
4.2
2.5
1.7
1Ø, 220-240V, 50Hz
Indoor
13.0
9.0
Outdoor
58
Indoor
44 +1
38+1
Outdoor
57 +1
3,050
1,950
1,250
13.0
8.5
5.5
9.3
9.0
8.8
Indoor
22
13
Outdoor
80
Indoor
1,080 x 314 x 181 888 x 287 x 170
Outdoor
870 x 800 x 320
Indoor
11.0
9.0
Outdoor
67
1,400
950
O
L.C.D Wireless
Liquid
1/4"(6.35)
Gas
1/2"(12.7)
O
O
Operation
A-Unit Only
A-Unit + B-Unit
B-Unit Only
Unit
Item
Cooling Capacity
Btu/h(kcal/h)
Moisture Removal
ℓ
/h
Power Source
ø, V, Hz
Air Circulation
m
3
/min
Noise Level
dB(A)
Input
W
Running Current
A
E.E.R.
Btu/h.w
Motor Output
W
Dimensions(W x H x D)
mm
Net. Weight
kg
Refrigerant(R-22)(at 7.5m)
g
Airflow Direction Control(Up & Down)
Remocon Type
Service Valve
Sleeping Operation
Drain Hose
2. LM-3061C2L/M
Summary of Contents for LM-3061B2L
Page 1: ...Multi Type Room Air Conditioner SERVICE MANUAL MODEL LM 3061H2L M LM 3061B2L LM 3061C2L M ...
Page 51: ... 51 Electronic Control Device LM 3061C2L M 1 Indoor MAIN P C B ASM LM 3061H2L M LM 3061B2L ...
Page 52: ... 52 2 Outdoor MAIN P C B ASM LM 3061H2L M LM 3061B2L 3 DISPLAY P C B ASM ...
Page 53: ... 53 Schematic Diagram 1 Indoor LM 3061H2L M LM 3061B2L ...
Page 54: ... 54 LM 3061C2L M ...
Page 55: ... 55 2 Outdoor LM 3061H2L M LM 3061B2L ...
Page 62: ... 62 Memo ...
Page 63: ...P No 3828A20023H December 2002 Printed in Korea ...