- 37 -
Disassembly of the parts (Indoor unit)
Warning :
Disconnect the unit from power supply before mak-
ing any checks.
Be sure the power switch is set to “OFF”.
To remove the Grille from the Chassis.
• Set the up-and-down air discharge louver to open
position (horizontally) by finger pressure.
• Remove the securing screws
• To remove the Grille, pull the lower left and right
side of the grille toward you (slightly tilted) and lift
it straight upward.
1. To remove the sensor, housing connect, earth
conductor & step motor conductor with sen-
sor holder, Motor, Evaporator & P.C.B.
Screw
Power
Conductor
Step Motor
Conductor
Earth
Conductor
Motor
Conductor
Sensor
Conductor