6. Repairing
4. Test Procedure
Test items should be sequential in the table shown as below. Due to limitation of GSM test set, the test
should be started under E-GSM mode and hand over to DCS1800. In PCS1900 mode, the test should
be started under PCS1900 mode.
Default setting of GSM test set and PSU is shown as follows:
LGE Internal Use Only
Copyright © 2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
(Internal Loss)
(Please measure cable loss on first set-up and calibrate it.)
CALL STATUS
IDLE
CELL STATUS
ACTIVE CELL
OPERATING MODE
E-GSM
Expected input level
TX Level 5 : 33dBm
Control Base station Broadcast
Broadcast ON
Control Base station Channel
20
Control Base station Amplitude
-85dBm
Mobile Phone Channel
62 ( could be changed ARFCN Mch )
Mobile Phone TX Level
5
Mobile Phone Timeslot
4
PSU output voltage
+3.8V +/- 0.05V
PSU maximum current limit
2500mA
CALL STATUS
IDLE
CELL STATUS
ACTIVE CELL
OPERATING MODE
PCS1900
Expected input level
TX Level 0 : 30dBm
Control Base station Broadcast
Broadcast ON
Control Base station Channel
512
Control Base station Amplitude
-85dBm
Mobile Phone Channel
661 ( could be changed ARFCN Mch )
Mobile Phone TX Level
0
Mobile Phone Timeslot
4
PSU output voltage
+3.8V +/- 0.05V
PSU maximum current limit
2800mA