14
INSTALLATION
•
Gas Nozzle Specifications
BURNER OUTPUT RATINGS; kW
LPG / Natural Gas
Burner
Rate
Nozzle Code
LPG
Natural
Gas
LPG
Natural
Gas
LF
3.3
3.3
0.93
1.30
LR
2.4
2.7
0.79
1.20
RR
2.4
2.7
0.79
1.20
RF
3.3
3.3
0.93
1.30
•
Bypass Nozzle Specifications
BURNER OUTPUT RATINGS; kW
LPG / Natural Gas
Burner
Rate
Bypass Nozzle
Code
LPG
Natural
Gas
LPG
Natural
Gas
LF
3.3
3.3
E
K
LR
2.4
2.7
J
E
RR
2.4
2.7
J
E
RF
3.3
3.3
E
K
NOTE
•
In case of "E" type bypass nozzles, use
existing ones in valves.
Prepare Gas Hob for Conversion
1
Turn off gas supply to the gas hob.
2
Turn off the electrical power to the gas hob.
CAUTION
•
If the gas supply to the gas hob is disconnected
for any reason see the installation instructions
for proper connection and safety precautions.
Getting Started
Nozzles and bypass nozzles have an code on the
side or top, denoting the location on the gas hob
where it is to be installed.
E
Nozzle code
Bypass
nozzle Code
0.93
Nozzle
Bypass nozzle
To convert.
Trivet
Nozzle
Valve
Shaft
Top plate
Burner
Knob
Decor Ring
Burner
Body
Bypass Nozzle
Valve
1
Remove trivets, burners and top plate.
2
Remove the brass nozzle in the chimney of each
burner using a 7 mm nut driver.
3
Install the natural gas nozzles into their correct
positions as described in the Nozzle Location
and Nozzle Specifications Table.
4
Remove the bypass nozzle of each valve using
a flat-blade screw driver.
5
Install the natural gas bypass nozzles into their
correct positions as described in the Bypass
Nozzle Specifications Table.
6
To prevent leakage, make sure the nozzles and
bypass nozzles are securely screwed into the
burner bodies and valves.
CAUTION
•
During reassemble the top plate, make sure
all valve shafts are concentric with respective
decor rings.