GHX-308A/616
HYBRID KEY TELEPHONE SYSTEM
Http://suryawardana.com
68
Range:
000-104 minutes (000: No reminder tone)
Default:
000 minutes
Procedure:
1. Press FLASH button and dial 08.
2. On a display phone, you will see this display:
M/W TONE TIMER 000-104
000
3. Enter 3 digits on the numeric keypad.
4. Press HOLD button.
CO RING DETECT TIMER (FLASH 10)
This parameter can be adjusted to all CO line ringing detections from all types of central offices and PBX's. When the
duration of the ringing signal form CO lines is matched with the ringing detection circuitry, the CO lines begin to ring at
assigned telephones.
Parameters:
This timer controls the time necessary to detect a CO line as ringing into the system.
Range:
2-9(x 100) msec
Default:
3 (x100) msec
Procedure:
1. Press FLASH and dial 10.
2. On a display phone, you will see this display:
CO RING DETECT 2 - 9
3
3. Enter 1 digit on the number keypad.
4. Press HOLD button.
HOLD PREFERENCE (FLASH 11)
Hold preference allows either exclusive hold or system hold as the primary hold on the first depression of the HOLD
button.
Parameters:
The system may be programmed to have either exclusive or system hold preferred. If exclusive hold is preferred,
depress HOLD button once for exclusive hold and twice for system hold when using a key telephone. If system hold is
preferred, depress HOLD button once for system hold and twice for exclusive hold.
Default:
System Hold
Procedure:
1. Press FLASH button and dial 11.
2. On a display phone, you will see this display:
HOLD PREFERENCE SYS-EXC
SYSTEM
3. To make a change, press the top left program button.
LED off: Exclusive hold