56
NO
Measured Power (AC)
5.7[mW] -10.7[mW]?
AC radiation 72mW
WDRV>2.05[V]?
NO
YES
YES
Execute ‘S4LPCHK.exe’ and
choose ‘3.White Power Check’.
Measured Power Under
0.1[mW]?
No
Execute ‘S4LPCHK.exe’ and
choose ‘4.DVD Laser Check’.
OK
WDRV level
50[%] -150[%]?
WDRV level
150[%] over?
FPD level
50[%] under?
Replace the P/U and execute LD
Power calibration.
Replace the FEP and execute LD
Power calibration.
Replace the P/U and execute
LD Power calibration.
Replace the P/U and execute LD
Power calibration.
Replace the FEP and execute
LD Power calibration.
No
No
FPD level
150[%] over?
No
No
Yes
Yes
Yes
Yes
NG1
Replace the P/U and execute LD
Power calibration.
Yes
NG3
NG2
NG4
NG5
Input value of the power meter by [10µW]
For example: Measured power is 15.55
[mW] -> Input value is 1555.
OK
Input value of the power meter by [µW]
For example: Measured power is 0.15
[mW] -> Input value is 150.
B
C