40
41
Test 2
{G{GTTTG
tGGwGv
Before measuring resistance, be sure to turn the power off and discharge voltage.
(When discharging, contact the metal plug of power cord with the ground.)
During diagnostic test, tE1 and tE2, an error occurs.
During operation, the heater does not turn off.
Difference between actual and sensed temperature is significant.
After turning power off, measure the resistance.
Short with metal between the NA6 connector’s
Pin
①
(Yellow Wire) and Pin
④
(Blue Wire) to
Controller.
• Check if control
and the 6-pin
connector are
properly
connected.
• Replace
controller
• Replace
thermistor.
Check if resistance is in the range of Table 1
when measuring resistance between
terminals after separating harness
from thermistor assembly connector.
Check harness-linking connector.
NO
NO
YES
YES
Table 1. Resistance for Thermistor Temperature.
Air TEMP.
[°F( )]
50°F (10 )
60°F (16 )
80°F (21 )
70°F (27 )
Air TEMP.
[°F( )]
90°F (32°C)
100°F (38°C)
110°F (43°C)
120°F (49°C)
RES.
[KΩ]
18.0
14.2
11.7
9.3
RES.
[KΩ]
7.7
6.2
5.2
4.3
RES.
[KΩ]
2.9
3.0
2.5
2.2
Air TEMP.
[°F( )]
130°F (54 )
140°F (60 )
150°F (66 )
160°F (71 )
Caution
Trouble Symptom
Measurement Condition
Metal or Wire
T
ake 6-pin Connector from
the Controller.
39
Summary of Contents for DLE3500 series
Page 13: ...13 3 3 Connect Inlet Hose 21 8 150 800 800 ...
Page 18: ...18 15 ...
Page 21: ...21 7 WIRING DIAGRAM 18 ELECTRIC DRYER GAS DRYER ...
Page 22: ...22 Main PCB Picture Electric Gas 19 ...
Page 24: ...24 21 ...
Page 25: ...25 22 ...
Page 27: ...27 Electric Dryer Table 1 Resistance for Thermistor Temperature 25 ...
Page 36: ...36 10 DIAGNOSTIC TEST 35 T ...
Page 60: ...60 13 EXPLODED VIEW 13 1 Control Panel and Plate Assembly A210 A211 A120 A140 A110 58 ...
Page 65: ...65 MAY 2018 PRINTED IN KOREA P No MFL69290420 ...