Test 3
tG{
Before measuring resistance, be sure to turn the power off and discharge voltage.
(When discharging, contact the metal plug of power cord with ground wire.)
Drum dose not rotate; no blower function, no heater function.
Turn the dryer’s power off, then measure resistance.
Is resistance below 3 between connector
BL2- (White wire) and WH4-
(Brown wire)?
Measure while door is closed.
• Replace control.
(Relay check)
• Check controller
connector.
• Check if door frame
presses door switch
knob.
• Check door switch.
• Check harness
connection.
• Replace control.
(Relay check)
• Check controller
connector.
• Replace outlet
• Thermostat.
(Refer to
‘component’)
• Check idler assembly.
• Drum belt cuts off
• Drum belt takes off
from motor pulley.
• Replace idler
switch.
Is resistance below 3 between connector
BL2- (White wire) and WH4-
(Yellow wire)?
Measure while door is closed.
Is resistance below 3 between connector
WH4- (Yellow wire) and WH4-
(Brown wire)?
Is resistance below 1 between terminals
of outlet thermostat attached to blower housing?
Does idle switch attached to motor bracket
operate level by drum belt?
(Not operating lever is normal.)
Is resistance below 1 between idler switch
terminals?
• Check motor. (Refer to ‘motor diagram & check’)
• Check if control connector is contacted.
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
Caution
Trouble Symptom
Measurement Condition
isY
~o[
40
Summary of Contents for DLE3500 series
Page 13: ...13 3 3 Connect Inlet Hose 21 8 150 800 800 ...
Page 18: ...18 15 ...
Page 21: ...21 7 WIRING DIAGRAM 18 ELECTRIC DRYER GAS DRYER ...
Page 22: ...22 Main PCB Picture Electric Gas 19 ...
Page 24: ...24 21 ...
Page 25: ...25 22 ...
Page 27: ...27 Electric Dryer Table 1 Resistance for Thermistor Temperature 25 ...
Page 36: ...36 10 DIAGNOSTIC TEST 35 T ...
Page 60: ...60 13 EXPLODED VIEW 13 1 Control Panel and Plate Assembly A210 A211 A120 A140 A110 58 ...
Page 65: ...65 MAY 2018 PRINTED IN KOREA P No MFL69290420 ...