34
35
33
9-2. Installation Test (Duct Check)
Once you have completed the installation of the
dryer, use this test to make sure the condition of the
exhaust system is adequate for proper operation of
the dryer. This test should be performed to alert you
to any serious problems in the exhaust system of
your home.
•
Your dryer features Flow Sense™, an innovative
sensing system that automatically detects
blockages and restrictions in dryer ductwork.
Keeping ductwork clean of lint buildup and free of
restrictions allows clothes to dry faster and reduces
energy use.
NOTE
•
The dryer should be cool before starting this test. If
the dryer was warmed up during installation, run the
Air Dry cycle for a few minutes to reduce the interior
temperature.
Activating the Installation Test
1
Remove the drying rack and literature, and
then close the door.
Do not load anything in the drum for this test, as
it may affect the accuracy of the results.
2
Press and hold the Signal and Temp. buttons
and then press the Power button.
(On models with a glass touch control panel,
press the
Power
button then IMMEDIATELY
press and hold the
Temp.
and
Signal
buttons.)
This button sequence activates the installation
test. The code
will display if the activation
is successful.
3
Press the START/PAUSE button.
The dryer will start the test, which will last a
few minutes. The heat will be turned on and the
temperatures in the drum will be measured.
4
Check the display for results.
During the test cycle, monitor the Flow Sense™
display on the control panel. If the Flow Sense™
LED is not turned on, when the cycle ends,
the exhaust system is adequate. If the exhaust
system is severely restricted, the Flow Sense™
LED will be turned on. Other problems may also
be shown with error codes. See the chart below
for error code details and solutions.
LED; turned on :
RESTRICTED
The Flow Sense™ LED indicates that the exhaust
system is severely restricted. Have the system
checked immediately, as performance will be poor.
5
End of cycle.
At the end of the test cycle,
will display.
The test cycle will end and the dryer will shut off
automatically after a short delay.
Summary of Contents for DLE3500 series
Page 13: ...13 3 3 Connect Inlet Hose 21 8 150 800 800 ...
Page 18: ...18 15 ...
Page 21: ...21 7 WIRING DIAGRAM 18 ELECTRIC DRYER GAS DRYER ...
Page 22: ...22 Main PCB Picture Electric Gas 19 ...
Page 24: ...24 21 ...
Page 25: ...25 22 ...
Page 27: ...27 Electric Dryer Table 1 Resistance for Thermistor Temperature 25 ...
Page 36: ...36 10 DIAGNOSTIC TEST 35 T ...
Page 60: ...60 13 EXPLODED VIEW 13 1 Control Panel and Plate Assembly A210 A211 A120 A140 A110 58 ...
Page 65: ...65 MAY 2018 PRINTED IN KOREA P No MFL69290420 ...