9
DIAGNOSTIC TEST
22
ACTIVATING THE DIAGNOSTIC TEST MODE
1. UNIT must be in standby (unit plugged in, display off)
2. Press POWER while pressing MORE TIME and LESS TIME simultaneously.
3. Press START/PAUSE button to advance through diagnostics.
1. This TEST should be used for Factory test /Service test. Do not use this DIAGNOSTIC TEST other than specified.
2. Activating the Heater manually with the Door open may trip the Thermostat attached to the Heater, therefore do not
activate it manually. (Do not press the door switch to operate the heater while the door is open )
Pressing the
START/PAUSE
None
Standard
Thermistor open
tE1
Thermistor shorted
tE2
Power off
OO
Motor runs
Displays Moisture Sensor Operation
If moisture sensor is contacted with
damp cloth. The display number is
below180 in normal condition
239 = Low
moisture
30 = High
moisture
Current Temp.
(5~70)
Current Temp.
(5~70)
Electric control
&
Temperature sensor
ELECTRIC TYPE
Motor+Heater1(2700W)
GAS TYPE
Motor
ELECTRIC TYPE
Motor+Heater2
(5400W)
GAS TYPE
Motor+Gas valve
Once
Motor+Controller
Motor, Heater off
Loads off, Controller off
Twice
3 times
4 times
5 times
CHECKING
ACTION
DISPLAY
CHECKPOINT
ELECTRIC TYPE Heater 1 is
energized - 2700 W
GAS TYPE is not opened
(Temperature in the drum is
displayed in degrees C.)
ELECTRIC TYPE: Heater 1 and
heater 2 are energized - 5400 W
GAS TYPE: Gas valve is energized
(Temperature in the drum is
displayed in degrees C.)
1nEd (Electric Dryer)
1ngd (Gas Dryer)
U0#
d0#
Main program Version