Service Manual 55
Ceiling Concealed Duct
Nominal Cooling Capacity
kcal/h(W)
Btu/h
Nominal Heating Capacity
kcal/h(W)
Btu/h
Air Circulation
H/M/L
CMM(CFM)
External Static Pressure
mmAq
Setting temperature range(cool/heat)
°C
Fan motor
Output
W
Model
No. of Poles
Input
W
Running Current
A
Capacitor
µF/Vac
Fan
Type
No. Used / Diameter
EA/inch(mm)
Noise Level
H/M/L
dB(A)
(Sound Press,1.5m)
Temperature controller
Coil
Tube Size (OD)
inch(mm)
Fins per inch
No. of Rows & Column
Dehumidification Rate
l/h
Dimensions (W*H*D)
inch(mm)
Net Weight
kg(lbs)
Piping Connection
Liquid
inch(mm)
Gas
inch(mm)
Drain hose (OD Ø)
inch(mm)
Packing Dimension (W*H*D)
inch(mm)
Stuffing Quantity
Without S/Parts
20/40ft
Indoor Unit Type
Ceiling Concealed Duct
Model
ABNH186HLAB
ABNH246HLAB
ABNH306GLAB
Notes:
1. Capacities are based on the following conditions:
Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB
- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB
- Interconnecting Piping Length 7.5m
- Level Difference of Zero.
Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB
- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB
- Interconnecting Piping Length 7.5 m
- Level Difference of Zero.
2. Capacities are Net Capacities.
3. Due to our policy of innovation some specifications may be changed without notification.
4536(5275)
6048(7034)
7560(8791)
18000
24000
30000
5116(5949)
6955(8089)
8694(10110)
20300
27600
34500
16.5/14.5/13(583/512/459) 18/16.5/14(636/583/494) 26.5/23/20(936/812/706)
8
8
10
18~30 / 16~30
18~30 / 16~30
18~30 / 16~30
118
118
211
IC-13450LG13C
IC-13450LG13C
IC-13450LG13J
4
4
4
180
180
300
0.92
0.92
1.34
6/370
6/370
6/370
Sirocco Fan
Sirocco Fan
Sirocco Fan
1/6.97(177)
1/6.97(177)
1/6.97(177)
36/34/32
38/36/34
40/38/35
Thermistor
Thermistor
Thermistor
0.275(7)
0.275(7)
0.275(7)
21
21
21
3R10C
3R10C
3R,12C
2.0 2.5
3.3
34.6*10.2*17.7(880*260*450)
34.6*10.2*17.7 (880*260*450)
46.5*11.7*17.7(1180*298*450)
35(77.2)
35(77.2)
38(84)
1/4 (6.35)
1/4 (6.35)
1/4 (6.35)
1/2 (12.7)
1/2 (12.7)
5/8 (15.88)
25.4
25.4
25.4
44.7*13.4*22.0(1135*340*565)
44.7*13.4*22.0 (1135*340*565) 56.5*14.8*22.9(1,435*375*582)
120/252
120/252
95/191
3. Specifications
For outdoor units Single Split
See chapter MPS Variable SINGLE-A(AUUH-B)
Application Split(Simultaneous operation)
See chapter MPS Variable SINGLE-A(AUUH-B)
Summary of Contents for ATNH126ELFB
Page 68: ...72 Universal System Air Conditioner II Outdoor Units Introduction 73 MPS Variable SINGLE A 75 ...
Page 82: ...86 Universal System Air Conditioner MPS Variable SINGLE A 4 Wiring Diagrams AUUH126B AUUH186B ...
Page 83: ...MPS Inverter SINGLE A Service Manual 87 AUUH246B AUUH306B ...
Page 84: ...MPS Inverter SINGLE A 88 Universal System Air Conditioner AUUH368B AUUH488B ...
Page 85: ...Service Manual 89 MPS Variable SINGLE A AUUH608B ...
Page 104: ...Electronic Control Device 108 Universal System Air Conditioner Ceiling Duct Type BH Series ...
Page 105: ...Electronic Control Device Service Manual 109 BG BR Series ...
Page 106: ...Electronic Control Device 110 Universal System Air Conditioner VE Series Ceiling Floor ...
Page 107: ...Electronic Control Device Service Manual 111 VB Series ...
Page 109: ...Schematic Diagram Service Manual 113 Ceiling Cassette Type ...
Page 110: ...Schematic Diagram 114 Universal System Air Conditioner Ceiling Duct Type ...
Page 111: ...Schematic Diagram Service Manual 115 Ceiling Floor ...
Page 151: ...P No 3828A22009F Printed in Korea ...