Room Air Conditioner
Installation
Piping Length And Elevation
• Capacity is based on standard length and maximum allowance length is on the basis of
reliability.
• Oil trap should be installed every 5~7meters (16.4~23.0ft).
In case more than 5m(16.4ft)
Outdoor unit
Indoor unit
A
B
Outdoor unit
Indoor unit
A
B
A
Oil trap
Outdoor unit
Indoor unit
B
9k(C/O)
Ø9.52(3/8")
Ø6.35(1/4")
7.5(25)
7.5(25)
15(49)
20(0.22)
9K(H/P),12k
Ø12.7(1/2")
Ø6.35(1/4")
7.5(25)
7.5(25)
15(49)
20(0.22)
18k(C/O)
Ø12.7(1/2")
Ø6.35(1/4")
7.5(25)
15(49)
30(98)
20(0.22)
18k(H/P),24k
Ø15.88(5/8")
Ø6.35(1/4")
7.5(25)
15(49)
30(98)
20(0.22)
Pipe Size
Capacity
(Btu/h)
Suction
Evap
Standard
Length m(ft)
Max. Elevation
m(ft)
Max. length
m(ft)
Additional Refrigerant
g/m(oz/ft)