- 41 -
Copyright ©2009 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Part 3 Control logic
6.1 Function
Working of outdoor fan are different in different models.
Some models are single fan some are two fan type.
6.2 Operating process
Control logic of outdoor fan depends on outdoor temperature
1. DC motor fan control
6. Outdoor Fan Control
Model
RPM
Base Step
Max Step
Min Step
1 Pahse
AUUW243D[LUU245HV]
670
700
200
AUUW423D[LUU425HV]
670
700
200
Outdoor Temperature
Cooling Step
Outdoor Temperature
Heating Step
41~46˚C
Base Step+2
22~26˚C
Base Step-4
38~41˚C
Base Step+1
18~22˚C
Base Step-3
28~38˚C
Base Step
14~18˚C
Base Step-2
24~28˚C
Base Step-1
10~14˚C
Base Step-1
18~24˚C
Base Step-2
4~10˚C
Base Step
14~18˚C
Base Step-3
0~4˚C
Base Step+1
9~14˚C
Base Step-4
-4~0˚C
Base Step+2
2~9˚C
Base Step-5
-8~-4˚C
Base Step+2
-3~2˚C
Base Step-6
-15~-8˚C
Base Step+2
Summary of Contents for APNH2433LAD