The wall you select should be strong and solid
enough to prevent vibration
1. Mount the installation plate on the wall with
type "A" screws. If mounting the unit on a
concrete wall, use anchor bolts.
• Mount the installation plate horizontally by
aligning the centerline using a level.
2. Measure the wall and mark the centerline. It
is also important to use caution concerning
the location of the installation plate-routing
of the wiring to power outlets is through the
walls typically. Drilling the hole through the
wall for piping connections must be done
safely.
How to fix installation plate
Installation Plate
Type "A" screw
Installation plate
Ø70mm
Left rear piping
Right rear piping
C
D
B
A
Ø70mm
(SQ, SR, ST, SU)
Left rear piping
Right rear piping
B
A
D
C
Installation plate
(SZ)
SQ(7k~9k)
75
12
80
12
SR(9k~12k)
0
40
20
40
ST(18k~24k)
105
0
210
0
SZ(7k)
35
33
156
33
SU(9k~12k)
92
44
67
44
CHASSIS (Grade)
Distance (mm)
A
B
C
D