ENGLISH
44
Set ID Function
This function allows you to assign a unique ID to the monitor to control it remotely from your PC.
For "Actual Data Structure (Base 16 • Base 10)", see page 47
1
Press the [Menu] button.
2
Use the , , , buttons to select
General
. Then press the
OK
button.
3
Use the , , , buttons to select
Set ID
. Then press the
OK
button.
4
Select a
Set ID
to assign. Then press the
OK
button. The Set ID can be a value from 1 to 10.
5
Press the
EXIT
button to exit (pressing the [Menu] button hides the OSD).
Communication Parameters
•
Baud rate: 9600 bps (UART)
•
Data length: 8 bits
•
Parity bit: None
•
Stop bit: 1 bit
•
Communication code: ASCII code
•
Crossed (reverse) cable used.