4-11. White Balance Calibration Instruction
A. Preparation for calibration
A-1. Version Matching of Video Wall Monitor F/W and SuperSign C for Working Compatibility
(1) IR receiver is needed for manual adjustment
(2) ‘Set ID’ setting must be done before calibration.
(3) Before calibration, it is necessary to turn on the monitor at least 2 hour.
A-2. Setting for calibration
48
Models
55LV77A-7BL, 55LV77A-5BL, 55LV75A-7BL, 55LV75A-5BL 47/55LV35A all
F/W
version
SOC
3.00.10 or later
3.00.01 or later
Micom
1.19.8 or later
8.02.0 or later
Models
55WV40MS
55WV70MD
47WV50BR
47WV30 all
F/W
version
SOC
3.24.03 or later
3.01.22 or later
3.00.14 or later
3.10.20 or later
Micom
1.14.3 or later
3.02.5 or later
1.17.1 or later
2.05.2 or later
SuperSign C
2.1.1.0
NOTE(Very Important!)
If the F/W version is lower than ones above you must update
SuperSign C
RS232C
: RS-232C connection
(out→in)