6-2. Avoid installing the in-door signage at out-door
NOTE
In door signage may not be covered by warranty, if it is installed in an out door
In order to install in-door signage at out-door, you have to consider below condition.
A. Keep the temperature 0
°
C ~ 40
°
C.
When designing the enclosure, the temperature inside the enclosure must be maintained
between 0
°
C and 40
°
C. (Refer to Openframe signage section 1-1)
B. Consider using a cooling & heater solution.
To maintain the temperature inside the enclosure, you should consider using a cooling
and heater solution such as an air conditioner, heat exchanger, or combined cooler
and heater depending on the external environment. (Please see below examples)
You can also employ an air flow circulation system and air curtain between the front
panel and the enclosure. (Refer to Openframe signage section 1-2)
C. Please install a cooling system when exposed to direct sun light
For Example-Using a canopy may prevent the enclosure temperature increase
due to direct sunlight. (Refer to Openframe signage section 1-5)
65