C
HAPTER
6
| VLAN Configuration
IEEE 802.1Q Tunneling
– 183 –
ES-4500G Series
Layer 2 Flow for Packets Coming into a Tunnel Uplink Port
An uplink port receives one of the following packets:
◆
Untagged
◆
One tag (CVLAN or SPVLAN)
◆
Double tag (CVLAN + SPVLAN)
The ingress process does source and destination lookups. If both lookups
are successful, the ingress process writes the packet to memory. Then the
egress process transmits the packet. Packets entering a QinQ uplink port
are processed in the following manner:
1.
If incoming packets are untagged, the PVID VLAN native tag is added.
2.
If the ether-type of an incoming packet (single or double tagged) is not
equal to the TPID of the uplink port, the VLAN tag is determined to be a
Customer VLAN (CVLAN) tag. The uplink port’s PVID VLAN native tag is
added to the packet. This outer tag is used for learning and switching
packets within the service provider’s network. The TPID must be
configured on a per port basis, and the verification cannot be disabled.
3.
If the ether-type of an incoming packet (single or double tagged) is
equal to the TPID of the uplink port, no new VLAN tag is added. If the
uplink port is not the member of the outer VLAN of the incoming
packets, the packet will be dropped when ingress filtering is enabled. If
ingress filtering is not enabled, the packet will still be forwarded. If the
VLAN is not listed in the VLAN table, the packet will be dropped.
4.
After successful source and destination lookups, the packet is double
tagged. The switch uses the TPID of 0x8100 to indicate that an
incoming packet is double-tagged. If the outer tag of an incoming
double-tagged packet is equal to the port TPID and the inner tag is
0x8100, it is treated as a double-tagged packet. If a single-tagged
packet has 0x8100 as its TPID, and port TPID is not 0x8100, a new
VLAN tag is added and it is also treated as double-tagged packet.
5.
If the destination address lookup fails, the packet is sent to all member
ports of the outer tag's VLAN.
6.
After packet classification, the packet is written to memory for
processing as a single-tagged or double-tagged packet.
7.
The switch sends the packet to the proper egress port.
8.
If the egress port is an untagged member of the SPVLAN, the outer tag
will be stripped. If it is a tagged member, the outgoing packet will have
two tags.
Summary of Contents for iPECS ES-4526G
Page 1: ...USER GUIDE User Manual ES 4550G ES 4526G Managed Layer 3 Stackable GE Switch ...
Page 38: ...CONTENTS 38 ES 4500G Series ...
Page 58: ...SECTION I Getting Started 58 ES 4500G Series ...
Page 70: ...CHAPTER 1 Introduction System Defaults 70 ES 4500G Series ...
Page 86: ...SECTION I Web Configuration 86 ES 4500G Series Multicast Filtering on page 413 ...
Page 196: ...CHAPTER 6 VLAN Configuration Configuring MAC based VLANs 196 ES 4500G Series ...
Page 204: ...CHAPTER 7 Address Table Settings Clearing the Dynamic Address Table 204 ES 4500G Series ...
Page 228: ...CHAPTER 8 Spanning Tree Algorithm Configuring Interface Settings for MSTP 228 ES 4500G Series ...
Page 230: ...CHAPTER 9 Rate Limit Configuration 230 ES 4500G Series Figure 106 Configuring Rate Limits ...
Page 260: ...CHAPTER 12 Quality of Service Attaching a Policy Map to a Port 260 ES 4500G Series ...
Page 478: ...CHAPTER 17 IP Configuration Setting the Switch s IP Address IP Version 6 478 ES 4500G Series ...
Page 528: ...CHAPTER 20 IP Services Forwarding UDP Service Requests 528 ES 4500G Series ...
Page 614: ...CHAPTER 22 Multicast Routing Configuring PIMv6 for IPv6 614 ES 4500G Series ...
Page 628: ...CHAPTER 23 Using the Command Line Interface CLI Command Groups 628 ES 4500G Series ...
Page 702: ...CHAPTER 26 SNMP Commands 702 ES 4500G Series ...
Page 710: ...CHAPTER 27 Remote Monitoring Commands 710 ES 4500G Series ...
Page 868: ...CHAPTER 34 Port Mirroring Commands Local Port Mirroring Commands 868 ES 4500G Series ...
Page 890: ...CHAPTER 37 Address Table Commands 890 ES 4500G Series ...
Page 1066: ...CHAPTER 43 LLDP Commands 1066 ES 4500G Series ...
Page 1076: ...CHAPTER 44 Domain Name Service Commands 1076 ES 4500G Series ...
Page 1286: ...CHAPTER 49 Multicast Routing Commands PIM Multicast Routing 1286 ES 4500G Series ...
Page 1288: ...SECTION I Appendices 1288 ES 4500G Series ...
Page 1294: ...APPENDIX A Software Specifications Management Information Bases 1294 ES 4500G Series ...
Page 1327: ...ES 4526G ES 4550G E042011 ST R01 150200000149A ...
Page 1328: ...APRIL 2011 ISSUE 1 0 ...