Adjustments
Media aligner roller adjustment
Complete the media aligner roller adjustment procedure when you replace the media aligner roller. Always print a copy
of the Quick Test Page before making any adjustments to the media aligner roller reference adjustment screw.
Note:
When replacing the media aligner roller, back the reference adjustment screw out far enough to remove the
old media aligner roller and install the new one. It is not necessary to remove the screw.
•
If you have just replaced the media aligner roller, go to
“Step A” on page 393
.
•
If you are only correcting the top margin skew, go to
“Step B” on page 393
.
•
If you are correcting the bottom margin skew or both top and bottom margin skew, go to
“Step C” on page 394
.
Step A
Set the initial position of the media aligner roller plate using a 3mm hex wrench at the access hole indicated in the
following image (left), to give a position roughly 20.5mm as shown in the image below (right). This is the nominal point
and should minimize the amount of adjustment needed.
Continue to
“Step B” on page 393
.
Step B
Print a copy of the Quick Test Page, and check the top alignment indicators printed on the test page. The difference in
the print location to the top edge of the paper between the left and right alignment indicators should be 0.5mm (one
dot) or less. Depending on the skew, turn the screw either clockwise or counterclockwise using a 3mm hex wrench,
and print a copy of the Quick Test Page to check the diamonds on the top and bottom margin. Continue adjusting the
screw as you check the results of each adjustment on a new test page until the top image skew is below 0.5mm. One
full 360-degree turn of the aligner screw will change the top edge skew by roughly 1mm (2 alignment indicator dots).
7463
Repair information
393
Summary of Contents for XM5163
Page 111: ...3 Remove the toner supply 4 Remove the imaging unit 7463 Repair information 481...
Page 116: ...15 Disconnect the three cables D 16 Remove the ten inch display 7463 Repair information 486...
Page 122: ...9 Remove the front scanner cover 7463 Repair information 492...
Page 131: ...14 Remove the five screws C 15 Disconnect the five cables D 7463 Repair information 501...
Page 135: ...14 Remove the five screws C 15 Disconnect the five cables D 7463 Repair information 505...
Page 211: ...11 Remove the scanner CCD 7463 Repair information 581...
Page 310: ...4 Remove the other four screws C from the front side of the frame 7463 Repair information 680...
Page 314: ...5 Release the latches A holding the sensor to the media feeder 7463 Repair information 684...
Page 345: ...4 Remove the other four screws C from the front side of the frame 7463 Repair information 715...
Page 349: ...5 Release the latches A holding the sensor to the media feeder 7463 Repair information 719...
Page 357: ...2 Remove the two screws C then remove the left cover 7463 Repair information 727...
Page 413: ...2 Remove the two screws C then remove the right cover 7463 Repair information 783...
Page 431: ...3 Remove the two screws A and then remove the shield 7463 Repair information 801...
Page 433: ...5 Move away the left inner frame to access the parts underneath 7463 Repair information 803...
Page 437: ...5 Move away the left inner frame to access the parts underneath 7463 Repair information 807...
Page 456: ...3 Remove the two screws A and then remove the shield 7463 Repair information 826...
Page 462: ...3 Remove the two screws A and then remove the shield 7463 Repair information 832...
Page 464: ...5 Move away the left inner frame to access the parts underneath 7463 Repair information 834...
Page 466: ...3 Remove the two screws A and then remove the shield 7463 Repair information 836...
Page 510: ...7463 880...