7.
Confirm that the LXP-5 and MRC are set to the same MIDI channel by
pressing the LEARN button on the LXP-5 while moving any of the sliders
on the MRC. The LED on the LXP-5 will flicker.
8*. To set the LXP-5 to the same state as the MRC, press
∗
to send the MRC
Setup parameters to the LXP-5. The parameter values displayed by the
LXP-5 will change to match those displayed on the MRC.
OR
To set the MRC to the same state as the LXP-5, press ENTER on the
MRC to send the LXP-5 parameters to the MRC. The parameters
displayed by the MRC will change to show the values received from the
LXP-5
9.
You can confirm that two-way communication has been established by
selecting a new register from the LXP-5 front panel and then pressing
ENTER on the MRC. The MRC’s displays will change to the parameter
values of the new register.
*
(Step 8 only needs to be done the first time communication is estab-
lished between the two units.)
With two-way communication, you can update the MRC values to match
those currently active in the LXP-5. This is particularly useful if you’ve
changed the LXP-5 from its front panel and want to transfer the new settings
to the MRC for further editing. To update the MRC simply press ENTER at
any time while you are in Machine Run Mode. This will automatically transfer
and display the active LXP-5 parameters.