Lexicon
300L Owner's Manual
3-4
-24 18 12
6
0
6 +12 ovld dB
L
R
The 300L, as shipped from the factory, is set to run Analog In at 48kHz. To
change the Analog Sampling rate, to slave-lock the 300L to an external digital
device, or to external system word clock, press CTRL to enter the 300L Control
mode. The first page defines the input and output structures of the 300L.
STA
CLK
DIN
INP
OUT
OFMT
This page allows you to view the current status of the box, (STA), define sample
clock speed (CLK), specify a digital Input connector (DIN), and select Input type
(INP), output type (OUT) and digital output format (OFMT).
STA
System Status (View only)
This slider lets you view (but not change) the current status of the system
parameters.
CLK
Analog Clock Rate
Press the button under the slider to show the current analog clock sample rate.
Use the slider to select a new clock sample rate. If a Digital clock has been
selected to master the 300L, the display will show the current sample rate.
DIN
Digital Input Connection
Before setting the 300L to receive Digital Word Clock, use this slider to designate
one digital input connector ( XLR, RCA or Optical) as the master for the system.
You can have all three connector ports occupied, but only one can be selected
as a master and audio source.
INP
Analog, Digital, or Both
Identify the type of connector which will be receiving digital clock (via DIN), then
select the Input type here. In SINGLE Setups there are three choices: ANALOG,
DIGITAL, or DIGital. Use the slider to select the type of input you wish
to use. If you select DIGITAL, and the system is properly locked, the display field
will briefly show “AES” or “SPDIF” to indicate the format of the incoming signal.
If the system does not detect valid word clock, or is not properly locked to
incoming word clock,a "BAD DIGITAL WORD CLOCK" message will be dis-
played as shown below. If you get this message, check all your cables, and other
settings.
!BAD DIGITAL
WORD CLOCK!
When you are running a Dual-Mono setup, the selections are: ANALOG,
DIGITAL, ANA-A DIG-B, ANA-B DIG-A. CASCADE Setups can be ANALOG
or DIGITAL.
Selecting Analog and/
or Digital Input
Summary of Contents for 300L -
Page 1: ...Digital Effects LARC Interface Owner s Manual 300L...
Page 8: ...1 1 Installing the 300L 1 Installing the 300L...
Page 22: ...2 1 System Overview 2 System Overview...
Page 30: ...3 1 System Operation 3 System Operation...
Page 63: ...Lexicon 300L Owner s Manual 3 34...
Page 64: ...4 1 The Algorithms and their Parameters 4 The Algorithms and their Parameters...
Page 101: ...Lexicon 300L Owner s Manual 4 38...
Page 102: ...5 1 The Presets 5 The Presets...
Page 131: ...5 30 Lexicon 300L Owner s Manual...
Page 132: ...6 1 Time Code Operation 6 Time Code Operation...
Page 142: ...7 1 MIDI Operation 7 MIDI Operation...
Page 152: ...8 1 Troubleshooting 8 Troubleshooting...