background image

DI-000-0EDSR-00A

PRODUCT INFORMATION

•  For technical assistance, contact us at 

1-800-824-3005

•  Visit our website at 

www.leviton.com

LIMITED 2 YEAR WARRANTY AND EXCLUSIONS

Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that 

this product at the time of its sale by Leviton is free of defects in materials and workmanship 

under normal and proper use for two years from the purchase date. Leviton’s only obligation 

is  to  correct  such  defects  by  repair  or  replacement,  at  its  option,  if  within  such  two  year 

period the product is returned prepaid, with proof of purchase date, and a description of the 

problem  to 

Leviton  Manufacturing  Co.,  Inc.,  Att:  Quality  Assurance  Department,  59-25 

Little Neck Parkway, Little Neck, New York 11362-2591.

 This warranty excludes and there 

is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void 

if  this  product  is  installed  improperly  or  in  an  improper  environment,  overloaded,  misused, 

opened, abused, or altered in any manner, or is not used under normal operating conditions or 

not in accordance with any labels or instructions. 

There are no other or implied warranties 

of  any  kind,  including  merchantability  and  fitness  for  a  particular  purpose

,  but  if  any 

implied  warranty  is  required  by  the  applicable  jurisdiction,  the  duration  of  any  such  implied 

warranty, including merchantability and fitness for a particular purpose, is limited to two years. 

Leviton is not liable for incidental, indirect, special, or consequential damages, including 

without  limitation,  damage  to,  or  loss  of  use  of,  any  equipment,  lost  sales  or  profits 

or delay or failure to perform this warranty obligation

. The remedies provided herein are 

the  exclusive  remedies  under  this  warranty,  whether  based  on  contract,  tort  or  otherwise.

Summary of Contents for PowerSwitch EDSR

Page 1: ...Enclosed Disconnect Switch with Receptacle EDSR Cat No EDSR Rated 30A 600VAC Max INSTALLATION INSTRUCTIONS DI 000 0EDSR 00A PowerSwitch ...

Page 2: ...ollowing DIN Rail mounted hardware A Rotary Switch 30A 660V with Normally Open Auxiliary Contact B Terminal Blocks Color Coded Blue terminal block is Neutral Green Yellow terminal blocks are ground 2 Inside Enclosure Base A Grounding Bracket with Screw B Four 4 Enclosure Mounting Feet with Screws Note Wall Mounting Hardware not included 3 Six 6 12 10 AWG Leads 3 Black 2 Green 1 White for internal ...

Page 3: ...cal codes and the installation instructions WARNING Risk of electrical shock Disconnect all power supplies to enclosure before exposing interior More than one supply disconnect may be required to de energize this equipment before servicing WARNING Receptacle MUST be installed BEFORE connection to a power supply 30A MAXIMUM receptacle rating refer to ratings tables and wiring diagrams WARNING Separ...

Page 4: ... secure to the enclosure base with the provided mounting screws 10 32 x 1 1 4 Torque to 10 12 in lbs 1 2 N m Conduit Hub Mounting Conduit Hub not included 1 Route wires Install 3 4 or 1 hub not included to conduit and enclosure For 3 4 hub drill a 1 1 16 mounting hole For a 1 hub drill a 1 5 16 mounting hole Ensure that the O ring seats on the enclosure base outside wall Install grounding bracket ...

Page 5: ... coded Ground Terminal refer to Figures 2 3 3 Strip Gages and Torques for LINE and LOAD terminals For Neutral and Ground terminals use 14 8 AWG conductors strip to 15 32 12 0 mm Torque 7 1 8 9 in lbs 0 8 1 N m For Rotary Switch terminals use 14 8 AWG conductors strip to 11 16 17 5 mm Torque 7 in lbs 0 8 N m For Auxiliary terminals use 18 14 AWG conductors strip to 5 16 8 0 mm Torque 7 1 8 9 in lbs...

Page 6: ...th 30A Gasket For 20A applications use 20A Gasket and 20A Gasket Clamp NOTE DO NOT MIX ASSEMBLY CONFIGURATIONS To Install SEAL COMPONENTS FOR A 20A RECEPTACLE FOR SAFETY MAKE SURE SWITCH IS IN THE OFF POSITION 1 Lift Receptacle Cover Unscrew pre assembled Gasket Clamp assembly and remove from box Set mounting screws aside 2 20A Gasket and Gasket Clamp are indentified with a 20A visible mark 30A Ga...

Page 7: ... chart page 7 for the list of mating configurations The EDSR will work with all 20A and 30A NEMA Configurations For an environmental rating of IP66 while in use a Leviton WetguardTM plug must be used Gasket Clamp 20A Rubber Gasket 20A Environmental Rating Label EDSR V Ribs Mounting Screws 4 Gasket Clamp Assembly 30A Rubber Gasket and Gasket Clamp are pre installed with EDSR ...

Page 8: ...d V0 Max CR V0 Max Std V0 Max CR V0 Max Std V0 Max Std V0 Max Std V0 Max Std V0 Max Std V0 Max Std V0 Max Std V0 Max Std V0 Max Std V0 Max Std Cat No 2310 23CM10 2320 23CM20 2330 23CM30 2340 2350 2410 24CM10 2420 24CM20 2430 24CM30 2510 2510 2520 2520 2530 2530 2610 26CM10 2620 26CM20 2630 2630 2640 2650 2710 27CM10 2720 27CM20 2730 2730 2740 2740 2810 2810 2820 2820 2830 2830 Plug Type Cat No Pow...

Page 9: ...5 NEMA L9 20 Wire Diagram 11 NEMA L23 20 Wire Diagram 10 NEMA L22 20 Wire Diagram 9 NEMA L21 20 G Y X G N L3 L2 L1 T3 T2 T1 G W G N L3 L2 L1 T3 T2 T1 G N X G Y L3 L2 L1 T3 T2 T1 G N L3 L2 L1 T3 T2 T1 W G G Z Y X G N L3 L2 L1 T3 T2 T1 G Z Y X G N L3 L2 L1 T3 T2 T1 G Y W X G N L3 L2 L1 T3 T2 T1 G Y X G N L3 L2 L1 T3 T2 T1 W G Z Y X G N L3 L2 L1 T3 T2 T1 W G Z Y X G N L3 L2 L1 T3 T2 T1 W G Z Y X G N ...

Page 10: ...m 22 NEMA L22 30 Wire Diagram 23 NEMA L23 30 Wire Diagram 21 NEMA L21 30 Wire Diagram 16 NEMA L9 30 G Y X G N L3 L2 L1 T3 T2 T1 G N G Y Z X W L3 L2 L1 T3 T2 T1 G N G Y Z X W L3 L2 L1 T3 T2 T1 G W Y X G N L3 L2 L1 T3 T2 T1 G N G Y Z X W L3 L2 L1 T3 T2 T1 G N G Y Z X L3 L2 L1 T3 T2 T1 G N G Y Z X L3 L2 L1 T3 T2 T1 G Y Z X G N L3 L2 L1 T3 T2 T1 G W G N L3 L2 L1 T3 T2 T1 W G G N L3 L2 L1 T3 T2 T1 G Y ...

Page 11: ...NOTES ...

Page 12: ... is disclaimed liability for labor for removal of this product or reinstallation This warranty is void if this product is installed improperly or in an improper environment overloaded misused opened abused or altered in any manner or is not used under normal operating conditions or not in accordance with any labels or instructions There are no other or implied warranties of any kind including merc...

Page 13: ...ATION LEVITON INSTRUCTION SHEET MANUAL SPECIFICATIONS H2D 3 12 08 Helvetica DI 000 0EDSR 00A Black N A Final fold size 50 Lb offset Overall size 5 5 X 8 5 Booklet Paper size Saddle Stitch OVERALL SIzE 11 0 2 3 8 5 5 5 Booklet 8 5 FINAL SIzE Cat No 1 PowerSwitch TM ...

Reviews: