background image

20A RECEPTACLE SEAL INSTALLATION (Figure 5)

 

NOTE:

 20A Receptacle seal components are 

only

 to be used when a 20A Receptacle is installed. 

If installing a 30A Receptacle no components are required to be replaced.
•  Leviton EDSR is pre-assembled with Gaskets for a 30A Receptacle. When using with a 

20A Receptacle, the 20A Gasket and Gasket Clamp (included) must be used along with a 

WETGUARD

TM

 Plug to maintain an environmental rating of IP66, UL Standard 50 and a NEMA 

environmental rating of 3R 4X and 12K.

•  All parts are self aligning to mating parts 

(refer to Figure 5)

NOTE:

 The Gasket, and the Gasket Clamp are a 

mated pair

. The parts are identified with a 

visible mark (“20A” or “30A”)

 to be used either for 20A or 30A installation. 

EDSR is shipped with a 30A Gasket Clamp. For 30A applications, mate with 30A Gasket. For 20A 

applications use 20A Gasket and 20A Gasket Clamp.

NOTE: DO NOT MIX ASSEMBLY CONFIGURATIONS.

TO INSTALL SEAL COMPONENTS FOR A 20A RECEPTACLE:

 

FOR SAFETY, MAKE SURE SWITCH IS IN THE "OFF" POSITION.
1.

 Lift Receptacle Cover. Unscrew pre-assembled Gasket Clamp assembly and remove from box. 

Set mounting screws aside.

2.

 20A Gasket and Gasket Clamp are indentified with a "20A" visible mark (30A Gasket and 

Gasket Clamp are marked "30A").

3.

 With Receptacle Cover open, align Gasket Clamp with rubber Gasket and place this loose 

assembly over the Receptacle Opening. Make sure that the circular 

“V”

 ribs of the Gasket  

are within the 

“V”

 grooves  of the Receptacle Opening and secure with (4) screws previously 

removed to 8-10 in. lbs. of torque. 

NOTE:

 New environmental ratings label for 4X, 12K & IP66, are included for device cover when 

using a mating Leviton 

WETGUARD

TM

 Plug.

5

Figure 4

EDSR Front View

Affix Receptacle

Voltage Label Here

Affix IP66

Ratings Label Here

Switch Handle

Receptacle Cover

Summary of Contents for PowerSwitch EDSR

Page 1: ...Enclosed Disconnect Switch with Receptacle EDSR Cat No EDSR Rated 30A 600VAC Max INSTALLATION INSTRUCTIONS DI 000 0EDSR 00A PowerSwitch ...

Page 2: ...ollowing DIN Rail mounted hardware A Rotary Switch 30A 660V with Normally Open Auxiliary Contact B Terminal Blocks Color Coded Blue terminal block is Neutral Green Yellow terminal blocks are ground 2 Inside Enclosure Base A Grounding Bracket with Screw B Four 4 Enclosure Mounting Feet with Screws Note Wall Mounting Hardware not included 3 Six 6 12 10 AWG Leads 3 Black 2 Green 1 White for internal ...

Page 3: ...cal codes and the installation instructions WARNING Risk of electrical shock Disconnect all power supplies to enclosure before exposing interior More than one supply disconnect may be required to de energize this equipment before servicing WARNING Receptacle MUST be installed BEFORE connection to a power supply 30A MAXIMUM receptacle rating refer to ratings tables and wiring diagrams WARNING Separ...

Page 4: ... secure to the enclosure base with the provided mounting screws 10 32 x 1 1 4 Torque to 10 12 in lbs 1 2 N m Conduit Hub Mounting Conduit Hub not included 1 Route wires Install 3 4 or 1 hub not included to conduit and enclosure For 3 4 hub drill a 1 1 16 mounting hole For a 1 hub drill a 1 5 16 mounting hole Ensure that the O ring seats on the enclosure base outside wall Install grounding bracket ...

Page 5: ... coded Ground Terminal refer to Figures 2 3 3 Strip Gages and Torques for LINE and LOAD terminals For Neutral and Ground terminals use 14 8 AWG conductors strip to 15 32 12 0 mm Torque 7 1 8 9 in lbs 0 8 1 N m For Rotary Switch terminals use 14 8 AWG conductors strip to 11 16 17 5 mm Torque 7 in lbs 0 8 N m For Auxiliary terminals use 18 14 AWG conductors strip to 5 16 8 0 mm Torque 7 1 8 9 in lbs...

Page 6: ...th 30A Gasket For 20A applications use 20A Gasket and 20A Gasket Clamp NOTE DO NOT MIX ASSEMBLY CONFIGURATIONS To Install SEAL COMPONENTS FOR A 20A RECEPTACLE FOR SAFETY MAKE SURE SWITCH IS IN THE OFF POSITION 1 Lift Receptacle Cover Unscrew pre assembled Gasket Clamp assembly and remove from box Set mounting screws aside 2 20A Gasket and Gasket Clamp are indentified with a 20A visible mark 30A Ga...

Page 7: ... chart page 7 for the list of mating configurations The EDSR will work with all 20A and 30A NEMA Configurations For an environmental rating of IP66 while in use a Leviton WetguardTM plug must be used Gasket Clamp 20A Rubber Gasket 20A Environmental Rating Label EDSR V Ribs Mounting Screws 4 Gasket Clamp Assembly 30A Rubber Gasket and Gasket Clamp are pre installed with EDSR ...

Page 8: ...d V0 Max CR V0 Max Std V0 Max CR V0 Max Std V0 Max Std V0 Max Std V0 Max Std V0 Max Std V0 Max Std V0 Max Std V0 Max Std V0 Max Std V0 Max Std Cat No 2310 23CM10 2320 23CM20 2330 23CM30 2340 2350 2410 24CM10 2420 24CM20 2430 24CM30 2510 2510 2520 2520 2530 2530 2610 26CM10 2620 26CM20 2630 2630 2640 2650 2710 27CM10 2720 27CM20 2730 2730 2740 2740 2810 2810 2820 2820 2830 2830 Plug Type Cat No Pow...

Page 9: ...5 NEMA L9 20 Wire Diagram 11 NEMA L23 20 Wire Diagram 10 NEMA L22 20 Wire Diagram 9 NEMA L21 20 G Y X G N L3 L2 L1 T3 T2 T1 G W G N L3 L2 L1 T3 T2 T1 G N X G Y L3 L2 L1 T3 T2 T1 G N L3 L2 L1 T3 T2 T1 W G G Z Y X G N L3 L2 L1 T3 T2 T1 G Z Y X G N L3 L2 L1 T3 T2 T1 G Y W X G N L3 L2 L1 T3 T2 T1 G Y X G N L3 L2 L1 T3 T2 T1 W G Z Y X G N L3 L2 L1 T3 T2 T1 W G Z Y X G N L3 L2 L1 T3 T2 T1 W G Z Y X G N ...

Page 10: ...m 22 NEMA L22 30 Wire Diagram 23 NEMA L23 30 Wire Diagram 21 NEMA L21 30 Wire Diagram 16 NEMA L9 30 G Y X G N L3 L2 L1 T3 T2 T1 G N G Y Z X W L3 L2 L1 T3 T2 T1 G N G Y Z X W L3 L2 L1 T3 T2 T1 G W Y X G N L3 L2 L1 T3 T2 T1 G N G Y Z X W L3 L2 L1 T3 T2 T1 G N G Y Z X L3 L2 L1 T3 T2 T1 G N G Y Z X L3 L2 L1 T3 T2 T1 G Y Z X G N L3 L2 L1 T3 T2 T1 G W G N L3 L2 L1 T3 T2 T1 W G G N L3 L2 L1 T3 T2 T1 G Y ...

Page 11: ...NOTES ...

Page 12: ... is disclaimed liability for labor for removal of this product or reinstallation This warranty is void if this product is installed improperly or in an improper environment overloaded misused opened abused or altered in any manner or is not used under normal operating conditions or not in accordance with any labels or instructions There are no other or implied warranties of any kind including merc...

Page 13: ...ATION LEVITON INSTRUCTION SHEET MANUAL SPECIFICATIONS H2D 3 12 08 Helvetica DI 000 0EDSR 00A Black N A Final fold size 50 Lb offset Overall size 5 5 X 8 5 Booklet Paper size Saddle Stitch OVERALL SIzE 11 0 2 3 8 5 5 5 Booklet 8 5 FINAL SIzE Cat No 1 PowerSwitch TM ...

Reviews: