FCC STATEMENT:
This device complies with Part 15 of the FCC Rules and ISED License-exempt RSS standard(s). Operation is subject 
to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept 
any interference received, including interference that may cause undesired operation.  Changes or modifications not 
expressly approved by Leviton could void the user’s authority to operate the equipment.
These limits are designed to provide reasonable protection against harmful interference in a commercial installation. 
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance 
with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that 
interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or 
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to 
correct the interference by one or more of the following measures: 
  - Reorient or relocate the receiving antenna. 
  - Increase the separation between the equipment and receiver. 
  - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 
  - Consult the dealer or an experienced radio/TV technician for help.
This Class A digital apparatus complies with Canadian CAN ICES-3(A)/NMB-3(A)

FCC SUPPLIER’S DECLARATION OF CONFORMITY:
This device manufactured by Leviton Manufacturing Co., Inc. 201 North Service Road, Melville, NY 11747. www.
leviton.com. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) 
This device may not cause harmful interference, and (2) this device must accept any interference received, including 
interference that may cause undesired operation.

TRADEMARK DISCLAIMER:
Leviton and the Leviton logo are trademarks of Leviton Manufacturing Co., Inc. Use herein of third party trademarks, 
service marks, trade names, brand names and/or product names are for informational purposes only, are/may be the 
trademarks of their respective owners; such use is not meant to imply affiliation, sponsorship, or endorsement. Modbus 

is a U.S. registered trademark of Schneider Electric USA, Inc.  
Belden is a trademark of Belden, Inc.

Leviton Manufacturing Co., Inc.
201 North Service Road, Melville, NY 11747

Visit Leviton’s website at www.leviton.com
© 2020 Leviton Manufacturing Co., Inc. All rights reserved.
Specifications and price subject to change at any time without notice.

LIMITED 5 YEAR WARRANTY AND EXCLUSIONS

Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale 

by Leviton is free of defects in materials and workmanship under normal and proper use for 5 years from the purchase date. 

Leviton’s only obligation is to correct such defects by repair or replacement, at its option. For details visit www.leviton.com or call  

1-800-824-3005. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This 

warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered 

in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other 

or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is 

required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular 

purpose, is limited to 5 years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without 

limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty 

obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.

FOR CANADA ONLY
For warranty information and/or product returns, residents of Canada should contact Leviton in writing at Leviton Manufacturing of 

Canada ULC to the attention of the Quality Assurance Department, 165 Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9 

or by telephone at 1 800 405-5320.

 For Technical Assistance Call: 1-800-824-3005 (USA Only) or 1-800-405-5320 (Canada Only) www.leviton.com

Summary of Contents for A8810-41M

Page 1: ...DI 000 A8810 00A Energy Management Hub and 3 Phase Meter EMX Data Acquisition System Cat No A8810 41M 41R Installation Guide...

Page 2: ......

Page 3: ...TABLE OF CONTENTS Warnings 1 Cautions 1 1 Getting Started 2 2 Site Location and Providing Power 4 3 Internal Component Configuration and Operation 7 4 Final Steps 11 5 Standard Statements 15...

Page 4: ...es See NFPA 70E in the USA or applicable local codes Product may use multiple voltage power sources Be sure all sources of power have been disconnected before servicing Do not depend on this product f...

Page 5: ...e included with the panel Enclosure Mounting Tabs Short Ethernet Patch Cable Ethernet Cable 7 Calibration Certificates Operating Manuals Engineering Drawings and Wiring Diagrams are located on the ins...

Page 6: ...round input terminals Power Meter Series 4100 Bi Directional 4DUMR split core or Rogowski coil versions Energy Monitoring Hub A8810 Power Supply Phoenix Contact Step PS 277AC 24DC 3 5A Separate 3 Phas...

Page 7: ...s for any necessary power current transformer and communications lines in the bottom of the enclosure 2 1 3 1 To maintain the warranty and integrity of the panel all holes punch outs for conduit and w...

Page 8: ...power inputs for meter reference voltage and panel power to allow the hub and meter to remain powered if the circuits being monitored need to be off 2 3 Connecting Current Transformers 2 3 1 CT input...

Page 9: ...X1 X2 C Black White Black X2 X1 X2 White Black X1 X2 L3 L2 L1 N X1 White A B C N X1 X2 A X1 X2 B X1 X2 C Black White Black X2 X1 X2 White Black X1 X2 L3 Diagram 1 1 Phase Line to Neutral 2 Wire System...

Page 10: ...el Number STEP PS 277AC 24DC 3 5 2904945 3 2 2 Nominal Input Voltage Range 100 VAC 277 VAC 3 2 3 Nominal Output Voltage 24 VDC 3 2 4 Nominal Output Current 3 5A 3 3 Leviton 4DUMR Power Meter Descripti...

Page 11: ...een 3 3 2 2 Press to go to the ADDR screen and through the address digits Use or to select the Modbus address default is 001 Leave at 001 unless otherwise instructed 3 2 2 3 Press to accept the value...

Page 12: ...ze in amps default is 100 3 3 3 7 Press to accept the value and go back to the S CT screen 3 3 4 To Enter the service type to be monitored 3 3 4 1 Navigate to the S SYS Set System Setup screen 3 3 4 2...

Page 13: ...1 Terminals and Port Diagram USB Port 3 INTERNAL COMPONENT CONFIGURATION AND OPERATION Power Terminal Menu and Select Buttons RS485 Modbus RTU Port Ethernet Port 3 4 2 LED Description Alive Blinks onc...

Page 14: ...g 3 5 1 2 To confirm you have established connection to the device do a ping to the IP address shown in the DAS s LCD display If no packets were lost the connection is working and you are ready to pro...

Page 15: ...RATION 3 5 1 6 Enter the desired admin user password in both boxes and click the Apply button 3 5 1 7 A Thank You message will be displayed confirming that the password was successfully set Click on t...

Page 16: ...p Check Allow Remote Access Click Apply 3 5 1 9 Once Remote Access Successfully Connects you will receive the message R Access Online Record Serial Number Pin 3 5 1 10 Call provider and provide Serial...

Page 17: ...s is 192 168 40 50 3 6 7 Scroll through the menu options and select Previous Menu to return to the home menu options This change will require a reboot 3 6 8 Click Select button to execute the reboot 3...

Page 18: ...rminated to local code Bottom knockouts are appropriately sealed and weatherproofed RS485 communication is terminated properly to terminal Power Supply Light DC OK is Green Meter LCD is on and cycling...

Page 19: ...e trademarks of their respective owners such use is not meant to imply affiliation sponsorship or endorsement Modbus is a U S registered trademark of Schneider Electric USA Inc Belden is a trademark o...

Reviews: