4
EN
Ermenrich LV50/LV60 PRO Laser Level
Caution!
Please remember that mains voltage in most European countries is 220–240V. If you want to use your device in a country with
a different mains voltage standard, remember that use of a converter is absolutely necessary.
Charging the device
Connect the UBS Type-C cable to the device and DC adapter (not included) via a USB plug and connect it to the AC power supply.
Attention! The
device operates from the AC power supply, as the voltage of the computer’s USB port is insufficient for the proper operation of the device.
Using
Slide the (3) switch to the unlocked position. Press (7) and hold it for 3 seconds to turn the device on or off. Press (7) to change the
brightness level.
WARNING:
When moving the laser level or storing it, keep the switch (3) locked.
Laser beams control buttons
On the laser level
On the remote control
Description
Blue button
V1
Controls the vertical laser beam at the front of the device
Green button
H
Controls the horizontal laser beam
Yellow button
V2
Controls the vertical laser beam on the side of the device
Auto-leveling mode
Unlock the device. All of the laser beams will light up. The power indicator light (11) is green. If the power indication is red and laser beams
flash frequently, place the device on a flatter surface. All three laser beams can be controlled by the (4)/(8)/(9) buttons. Lock the device and
turn it off.
Locked mode
Lock the device. Press (7) and hold it for 3 seconds. All of the laser beams will be flashing. The power indicator light (11) is red. In the locked
mode, the device can be angled as needed. In this way, it is possible to project inclined lines and the autocalibration will be switched off.
Brightness adjustment
When the device is in self-leveling or locked mode, press (7). There are four brightness levels. Press (12) on the remote control to change the
brightness level to save energy.
Pulse mode
Unlock the device. Press (7) and hold it for 3 seconds to enter pulse mode. The power indicator light (11) will be flashing.
Note!
Brightness
adjustment is not possible in pulse mode.
Specifications
Laser level
Laser color
green
Laser wavelength
505–550nm
Working distance
30m
Laser class
class II
Expanded angle
3D, 12 lines, 360° horizontal, 360° vertical
Brightness levels and working time
4 levels of brightness:
1 = 6h
2 = 9h
3 = 15h
4 = 30h
Compensation range
4°±1°
Level accuracy
±1.5mm/5m
Tripod adapter
1/4"
Protection level
IP54
Power supply
4000mA·h built-in lithium battery, USB Type-C
Operating temperature range
-10… +50°C (14…122°F)
Dimensions
98.5x96x73mm (3.8x3.7x2.8in)