Chapter 13
| Basic Administration Protocols
Connectivity Fault Management
– 508 –
■
HIT – Target located on this device.
Web Interface
To show information about link trace operations launched from this device:
1.
Click Administration, CFM.
2.
Select Show Information from the Step list.
3.
Select Show Link Trace Cache from the Action list.
Figure 326: Showing the Link Trace Cache
Displaying Fault
Notification Settings
Use the Administration > CFM > Show Information (Show Fault Notification
Generator) page to display configuration settings for the fault notification
generator.
Parameters
These parameters are displayed:
◆
MEP ID
– Maintenance end point identifier.
◆
MD Name
– Maintenance domain name.
◆
MA Name
– Maintenance association name.
◆
Highest Defect
– The highest defect that will generate a fault alarm.
(This is disabled by default.)
◆
Lowest Alarm
– The lowest defect that will generate a fault alarm
16
.
◆
Alarm Time
– The time a defect must exist before a fault alarm is issued
.
◆
Reset Time
– The time after a fault alarm has been issued, and no defect exists,
before another fault alarm can be issued
.
16. See
Summary of Contents for GTL-2881
Page 34: ...Section I Getting Started 34 ...
Page 48: ...Section II Web Configuration 48 Unicast Routing on page 651 ...
Page 151: ...Chapter 4 Interface Configuration VLAN Trunking 151 Figure 69 Configuring VLAN Trunking ...
Page 152: ...Chapter 4 Interface Configuration VLAN Trunking 152 ...
Page 230: ...Chapter 8 Congestion Control Automatic Traffic Control 230 ...
Page 596: ...Chapter 14 Multicast Filtering Multicast VLAN Registration for IPv6 596 ...
Page 620: ...Chapter 15 IP Configuration Setting the Switch s IP Address IP Version 6 620 ...
Page 672: ...Section III Appendices 672 ...
Page 678: ...Appendix A Software Specifications Management Information Bases 678 ...
Page 688: ...Appendix C License Statement GPL Code Statement Notification of Compliance 688 ...
Page 696: ...Glossary 696 ...
Page 706: ...GTL 2881 GTL 2882 E112016 ST R01 ...