18
5.23. Initialization of Gate to Initial Set-up from Production.
Remote initialization of GB 102 can be carried out using SMS message. All
adjustable parameters except PIN numbers and blocking of SIM card are set to
initial values set from production. At the same time RESET is carried out.
Implementation of INIT makes GSM Gate during 20 sec. If you are doing this
implementation through the phone, hang up after return dialing tone in the phone
receiver.
Dial Command
SMS Command
Default
3400#
INIT
Hardware initialization (only GB 102 x2x):
●
disconnect the GB 102 power supply
●
connect PIN „I“ with „
┴
“ of the micro Fit connector
●
connect the GB 102 unit to power supply
●
LED indicating PWR will blink 3 times
●
remove connection of PINs - the gateway will go into default settings at 20 s