background image

 
 

 

7

 

 
 
 
 
 

4.2. Configuring gateway from PC connected over remote access 

 

To  use  the  remote  access  possibility  it  is  necessary  to  have  the  data  services 
activated on the SIM cart used in the GB 102 and the remote access connection 
must be enabled in configuration of GB 102. 
  
It is recommended to use a PC GSM modem for the remote access. Connection 
parameters  for  remote  access  can  be  found  in  Control  Panel  -  Settings  - 
Communication  Settings  -  Remote  Access.  Connect  to  the  GB  102  using  the 
GSM network and continue in changing configuration using the Control Panel. 

 

4.3. Configuring via Phone Line 

 
 

 

Configuring GB 102 via phone line is performed by dialing numbers on a phone 
with tone dialing. 

 

1. 

Connect the phone to the GB 102 – pick up the receiver, in case of need 
when using a PBX dial the access code of the extension line connected 
to the GB 102. You should hear the dial tone. 

2. 

Dial  #pppp#,  where  pppp  are  four  digits  of  gate  PIN.  PIN  is  set  1234 
from production. After entering correct PIN you will hear tone configuring 
tone (··    ··    ··  ). 

3. 

Enter particular setting parameters. Dial 4 digits of instruction followed by 
value of parameter for particular instruction. 

4. 

End entering of instruction by dialing #. Time control is 1 minute after last 
dial.  After  entering  correct  instruction  you  will  hear  tone  “Configuring” 
again and another instruction can be entered. 

5. 

Configuring mode will be exited by hang-up of receiver. 

 

If  you  enter  invalid  configuration  command  you  will  hear  the  busy  tone.  In  this 
case  continue  the  settings  by  entering  the  command  again  or  end  the  settings 
mode  by  hanging  up.  If  valid  commands  were  entered  before,  the  new  settings 
will be saved. If there is the programming symbol “*” set instead of “#” then use “*” 
in all commands. 

 

4.4. Configuring and Operating by SMS Messages 

 

Incoming SMS messages are processed - command messages are executed and 
all  others  can  be  ether  deleted  or  forwarded  to  a  phone  number  preset  in 
configuration.  

 

Summary of Contents for GB 102 122

Page 1: ...GB 102 Series with Built in GSM Module Two way Converter of Phone Line to GSM USER GUIDE LEVEL LEVEL LEVEL LEVEL GSM GATE DAISYGATE...

Page 2: ...1...

Page 3: ...onnect either direct or extension phone lines to connector ATTENTION GSM Gates are not subject of homologation by T Czech Telecommunication Office Entrepreneur is therefore obliged to ensure that call...

Page 4: ...er Is Sent 11 5 9 Set up of Dial Tone Type 12 5 10 Set up of Programming Symbol or 12 5 11 Set up of Tariffs 12 5 12 Number for Information SMS Messages 13 5 13 Set up of Number for Monthly Upkeep Cal...

Page 5: ...001 GSM antenna 3 dB ED 102 001 Convertor with cables software for configuration Mounting set wall plugs screws and drill template Conector micro Fit 6 grip User Guide Note included in the set access...

Page 6: ...f connecting cable for installation should not be shorter than 5 meters so that it is possible to place GSM Gate and antenna in sufficient distance from exchange However phone cable should not be long...

Page 7: ...ximum adjustment of gate GB 102 to environment and user s requirements can be set by programming Parameter configuration change can be performed using Control Panel software connected via serial line...

Page 8: ...al tone 2 Dial pppp where pppp are four digits of gate PIN PIN is set 1234 from production After entering correct PIN you will hear tone configuring tone 3 Enter particular setting parameters Dial 4 d...

Page 9: ...ing of an instruction is always sent back to sender s cell phone Parameter NOTIFYSMS means that the preset number will receive all reset messages and low prepaid credit reports If parameter INFOSMS is...

Page 10: ...number dialed before interconnection when connecting call to transmitter with GSM gate This function allows reconstruction of originally dialed number by adding of removed pre selection Dial Command...

Page 11: ...card according to dialed number parameter SIMDIR set numbers of pre selections from longest to shortest Priority of evaluation goes from above 5 4 Code for Disallowed Directions Code for disallowed di...

Page 12: ...nd means time in tenths of seconds tm 0 0 9 9 s 5 6 Set up of Waiting Time for Dial After picking up GSM gate gives you dialing tone which notifies you about possibility of dialing of number After set...

Page 13: ...sion exchange for any service concurrent with functions of GSM gate it is possible to set that symbol is used exclusively in all instructions instead of symbol Dial Command SMS Command Default 1100x F...

Page 14: ...Default 2100x MCALL x Not activated from production Where x is 1 to 20 digits of number Removal of values is carried out by instruction 2100 or by SMS message MCALL point represents data If you want...

Page 15: ...5 16 Set up of Numbers for ALARM Calling When one of the inputs 1 5 is activated only GB 102 x2x the preset phone number will be dialed and the called party will hear warning tone from GB 102 first th...

Page 16: ...s required logical level of 0 or 1 Recommended linkage of outputs with galvanic detachment example for output No 1 Drawing of connector on GB 102 5 19 Set up of Sensitivity of Audio Input Instruction...

Page 17: ...eature and x 0 disables the feature Delay of Additional DTMF Transmission This parameter determines the delay before the additional DTMF selection starts after the phone call is answered Additional DT...

Page 18: ...s suitable for directing phone calls to PBX s with ISDN dialing in Mode 1 additional dial will replace the enter prefix dial of short code selection coming to the gateway with phone number of the resu...

Page 19: ...out Implementation of INIT makes GSM Gate during 20 sec If you are doing this implementation through the phone hang up after return dialing tone in the phone receiver Dial Command SMS Command Default...

Page 20: ...3 x ADIR4 x ADIR5 x ADIR6 x ADIR7 x ADIR8 x ADIR9 x ADIR10 x ADIR11 x ADIR12 x ADIR13 x ADIR14 x ADIR15 x ADIR16 x x 1 7 digits or x clears out parameter value 1 2 3 4 5 6 7 8 9 0 Code for disallowed...

Page 21: ...Alarmx Set up of outputs 260xy IOx y x input 1 5 y 0 or 1 all 1 Setting audio in 2701x AUDIOINP x x 0 100 64 Setting audio out 2702x AUDIOOUT x x 0 100 64 Virtual tie line DTMF pulse width 3000x TIEWI...

Page 22: ...cell ID number used by device CELLID GSM signal strength SIGNAL 0 min 36 max Complete information about binary inputs and outputs status IOS Find out prepaid credit for each SIM card CREDITMODE x x 0...

Page 23: ...ts automatically you can also run the setup exe file on the CD Please follow the installation guide dialog 7 2 Control Panel Program answers the purpose of comfortable and transparent configuration of...

Page 24: ...ector RJ 11 SMS inputs micro Fit No 1 5 log 0 0 0 5 V log 1 2 5 V SMS outputs micro Fit No 1 5 log 0 max 0 4 V max Iz 5 mA log 1 2 3 3 V at Iz 0 1mA micro Fit 12 V DC max load 200 mA GSM network GSM 9...

Page 25: ...24 GUARANTEE CERTIFICATE Product name Type Production number Date of sale Signature Seller Address Phone Stamp Date of Receipt Date of Shipping Description of Defect...

Page 26: ...ee Certificate damage of product caused by natural disaster during transport by unsuitable positioning unsuitable handling and operation of device in unsuitable conditions or in case of damage or remo...

Page 27: ...26...

Page 28: ...27 GB 102 2xx 1 03 LEVEL 2005 LEVEL Ltd Plhovsk 1997 N chod 547 01 CZECH REPUBLIC www levelna cz...

Reviews: