7
4.2. Configuring gateway from PC connected over remote access
To use the remote access possibility it is necessary to have the data services
activated on the SIM cart used in the GB 102 and the remote access connection
must be enabled in configuration of GB 102.
It is recommended to use a PC GSM modem for the remote access. Connection
parameters for remote access can be found in Control Panel - Settings -
Communication Settings - Remote Access. Connect to the GB 102 using the
GSM network and continue in changing configuration using the Control Panel.
4.3. Configuring via Phone Line
Configuring GB 102 via phone line is performed by dialing numbers on a phone
with tone dialing.
1.
Connect the phone to the GB 102 – pick up the receiver, in case of need
when using a PBX dial the access code of the extension line connected
to the GB 102. You should hear the dial tone.
2.
Dial #pppp#, where pppp are four digits of gate PIN. PIN is set 1234
from production. After entering correct PIN you will hear tone configuring
tone (·· ·· ·· ).
3.
Enter particular setting parameters. Dial 4 digits of instruction followed by
value of parameter for particular instruction.
4.
End entering of instruction by dialing #. Time control is 1 minute after last
dial. After entering correct instruction you will hear tone “Configuring”
again and another instruction can be entered.
5.
Configuring mode will be exited by hang-up of receiver.
If you enter invalid configuration command you will hear the busy tone. In this
case continue the settings by entering the command again or end the settings
mode by hanging up. If valid commands were entered before, the new settings
will be saved. If there is the programming symbol “*” set instead of “#” then use “*”
in all commands.
4.4. Configuring and Operating by SMS Messages
Incoming SMS messages are processed - command messages are executed and
all others can be ether deleted or forwarded to a phone number preset in
configuration.