Multiplex operation
In this operating mode the mutual interference of adjacent sensors can be reliably avoided. For this purpose, each sensor is wired
with a separate output of the control.
The devices operate in multiplex operation with a cyclically time-delayed transmission pulse and are switched to a passive state
outside of the active phase.
Multiplex operation wiring schematic
Timing diagram for multiplex operation
Resetting to factory settings
The sensor can be reset to the factory setting (one switching point each at 3500 mm or 6000 mm).
Resetting to factory settings
1.When switching on the supply voltage (during power-on), press the teach button for > 5s.
2.Release the button. The green, yellow and blue LEDs flash alternately and very quickly for a brief time.
The sensor was reset to the factory setting:
switching output OUT 1: NO contact, 1 switching point at 3500 mm or 6000 mm (static 1-point teach),
switching output OUT 2: NC contact, 1 switching point at 3500 mm or 6000 mm (static 1-point teach).
Sensor 2
Sensor 1
Sensor n
NOTE
Please make certain that the wiring is performed accord
-
ing to the connection diagram.
The Sync/MUX pin 5 of each sensor must be connected
with a separate output of the control.
The control generates the time-delayed multiplex sig
-
nals for all sensors.
+10 - 30 VDC
MUX pulse
from the control
Time-delayed
+10 - 30 VDC MUX pulse
from the control
Time-delayed
+10 - 30 VDC MUX pulse
from the control
t
resp
t
resp
t
resp
t
resp
t
resp
t
resp
Sensor 1
Sensor 2
Sensor 3
Scanning range
Response time of the switching outputs t
resp
250 … 3500mm
250ms
350 … 6000mm
500ms