background image

HTU330-3500…-M12 - 01

2020/08/05

HTU330-6000…-M12 - 01

Technical data

Ultrasonic specifications

HTU330-3500.3/…-M12

HTU330-6000.3/…-M12

Scanning range 

1)

1) At 20°C

250 … 3500mm 

2)

 

2) Target: 200mm x 200mm plate

350 … 6000mm 

3)

 

3) Target: 400mm x 400mm plate

Adjustment range

250 … 3500mm

350 … 6000mm

Ultrasonic frequency

112kHz

75kHz

Typ. opening angle

± 7°

± 9°

Resolution

5mm

6mm

Direction of beam

Axial

Axial

Reproducibility

± 0.5% 

1)

 

4)

4) From end value

± 0.5% 

1)

 

4)

Switching hysteresis

1% 

4)

 

1% 

4)

 

Temperature drift

e

8% 

5)

5) Over the temperature range -20°C … +70°C

e

8% 

5)

 

Timing

Switching frequency

2Hz

1Hz

Response time

250ms

500ms

Readiness delay 

e

500ms

e

500ms

Electrical data

Operating voltage U

B 6)

 

6) For UL applications: use is permitted exclusively in Class 2 circuits according to NEC

12 … 30V DC (incl. ± 5% residual ripple) 

Residual ripple

s

5% of U

B

Open-circuit current

e

50mA

Switching output / Function

…/4P… 2 independent PNP transistor switching outputs 

OUT 1 (pin 4): NO contact preset

OUT 2 (pin 5): NC contact preset

…/2N… 2 independent NPN transistor switching outputs 

OUT 1 (pin 4): NO contact preset

OUT 2 (pin 5): NC contact preset

Output current

Max. 100mA

Switching range adjustment

1-point teach: teach-in button 2 … 7s, 

2-point teach: teach-in button 7 … 12s

Changeover 

NO/NC

Teach-in button > 12s

Indicators

Yellow LED 

OUT1: object detected

Blue LED 

OUT2: object detected

Flashing yellow or blue LED

Teach-in

Flashing green and yellow/blue LEDs

Teaching error

Green LED 

Object within the scanning range

Mechanical data 

Housing 

Plastic (PBT)

Active surface

Epoxy resin, glass fiber reinforced

Weight 

140g / 170g

Ultrasonic transducer

Piezoceramic 

7)

7) The ceramic material of the ultrasonic transducer contains lead zirconium titanate (PZT)

Connection type 

M12 connector, 5-pin

Fitting position

Any

Environmental data

Ambient temp. (operation/storage) 

-20° … +70°C/-20° … +70°C 

Protective circuit 

8)

8) 1=short-circuit and overload protection, 2=polarity reversal protection, 3=wire break and inductive protection

1, 2, 3

VDE protection class

III

Degree of protection 

IP 67

Standards applied

EN 60947-5-2

Certifications

UL 508, CSA C22.2 No.14-13 

6)

 

9)

 

9) These proximity switches shall be used with UL Listed Cable assemblies rated 30V, 0.5A min, 

in the field installation, or equivalent (categories: CYJV/CYJV7 or PVVA/PVVA7)

Diagrams

HTU330-3500.3/…-M12

0

1000

2000

3000

4000

y1

y2

-400

-200

0

200

400

-300

-100

100

300

Object distance x [mm]

W

idth

 y of

 th

e so

und

 co

ne 

[m

m]

Typ. response behavior 

(plate 200x200mm)

0

1000

2000

3000

4000

y1

y2

-400

-200

0

200

400

-300

-100

100

300

Object distance x [mm]

W

id

th

 y of

 th

e so

und

 co

ne 

[m

m]

Typ. response behavior 

(rod Ø 25mm)

HTU330-6000.3/…-M12

Notes

Observe intended use!

This product is not a safety 

sensor and is not intended 

as personnel protection.

The product may only be put 

into operation by competent 

persons.

Only use the product in ac

-

cordance with its intended 

use.

y1

y2

-600

-400

0

200

-200

400

600

0

2000

4000

6000

Object distance x [mm]

Wi

dt

h y 

of t

he 

sou

nd 

con

e [m

m

]

Typ. response behavior 

(plate 200x200mm)

y1

y2

-600

-400

0

200

-200

400

600

0

2000

4000

6000

Object distance x [mm]

W

idth

 y o

f th

e so

un

d co

ne

 [m

m]

Typ. response behavior 

(rod Ø 25mm)

Object distance [mm]

Target (fixed):

plate or rod

Sound cone

= f (

D

,x)

HTU330

Summary of Contents for HTU330 Series

Page 1: ... point can be taught NO NC function reversible 2 independent switching outputs PNP or NPN NEW Both outputs can easily be taught using a button NEW Stable plastic design NEW Temperature compensated scanning range 250 3500mm 350 6000mm Accessories available separately Mounting systems Cables with M12 connector KD Dimensioned drawing A Active sensor surface B Teach in button C Indicator diodes DMU330...

Page 2: ... Plastic PBT Active surface Epoxy resin glass fiber reinforced Weight 140g 170g Ultrasonic transducer Piezoceramic 7 7 The ceramic material of the ultrasonic transducer contains lead zirconium titanate PZT Connection type M12 connector 5 pin Fitting position Any Environmental data Ambient temp operation storage 20 70 C 20 70 C Protective circuit 8 8 1 short circuit and overload protection 2 polari...

Page 3: ...connector pin 4 black cable wire OUT1 4 PNP output NO contact preset P PNP output NC contact preset 2 NPN output NO contact preset N NPN output NC contact preset Pin assignment of connector pin 2 white cable wire Analog OUT OUT2 4 PNP output NO contact preset P PNP output NC contact preset 2 NPN output NO contact preset N NPN output NC contact preset C Analog output 4 20mA V Analog output 0 10V Pi...

Page 4: ...LED OFF Green LED ON Distance Hysteresis Switching point Scanning range OUT not active Yellow blue LED OFF Green LED OFF OUT not active Yellow blue LED OFF Green LED OFF Dead zone Sensor OUT not active Yellow blue LED OFF Green LED ON OUT active Yellow blue LED ON Green LED OFF Distance Hysteresis Switching point Scanning range OUT active Yellow blue LED ON Green LED OFF OUT active Yellow blue LED...

Page 5: ...ior with 2 point window teach as a function of the switching function 1 Place object at desired switching distance 1 First place object at desired switching distance for switching point 1 2 To adjust the selected output press the teach button for 2 7s until the yellow LED OUT 1 or blue LED OUT 2 flashes at 3Hz The current state of the selected output is frozen during the adjustment process 2 To ad...

Page 6: ...d the switching output is changed to the opposite state toggled First activate the previously described teach mode for output OUT 1 or OUT 2 Changeover of the switching function 1 To change the switching function of the selected output press the teach button for longer than 12s The current state of the selected output is frozen during the adjustment process 2 The green and yellow blue LEDs flash a...

Page 7: ...gram A synchronization pulse from the control activates synchronous operation The devices work in synchronous operation with a simultaneous transmission pulse The response time of the individual sensors in the network corresponds approximately to that of a single sensor Synchronous operation wiring schematic Timing diagram for synchronous operation Working distance Minimum mounting distance 1 500m...

Page 8: ...ease the button The green yellow and blue LEDs flash alternately and very quickly for a brief time The sensor was reset to the factory setting switching output OUT 1 NO contact 1 switching point at 3500 mm or 6000 mm static 1 point teach switching output OUT 2 NC contact 1 switching point at 3500 mm or 6000 mm static 1 point teach Sensor 2 Sensor 1 Sensor n NOTE Please make certain that the wiring...

Reviews: