Technical data
Ultrasonic specifications
HTU330-3500.3/…-M12
HTU330-6000.3/…-M12
Scanning range
1)
1) At 20°C
250 … 3500mm
2)
2) Target: 200mm x 200mm plate
350 … 6000mm
3)
3) Target: 400mm x 400mm plate
Adjustment range
250 … 3500mm
350 … 6000mm
Ultrasonic frequency
112kHz
75kHz
Typ. opening angle
± 7°
± 9°
Resolution
5mm
6mm
Direction of beam
Axial
Axial
Reproducibility
± 0.5%
1)
4)
4) From end value
± 0.5%
1)
4)
Switching hysteresis
1%
4)
1%
4)
Temperature drift
e
8%
5)
5) Over the temperature range -20°C … +70°C
e
8%
5)
Timing
Switching frequency
2Hz
1Hz
Response time
250ms
500ms
Readiness delay
e
500ms
e
500ms
Electrical data
Operating voltage U
B 6)
6) For UL applications: use is permitted exclusively in Class 2 circuits according to NEC
12 … 30V DC (incl. ± 5% residual ripple)
Residual ripple
s
5% of U
B
Open-circuit current
e
50mA
Switching output / Function
…/4P… 2 independent PNP transistor switching outputs
OUT 1 (pin 4): NO contact preset
OUT 2 (pin 5): NC contact preset
…/2N… 2 independent NPN transistor switching outputs
OUT 1 (pin 4): NO contact preset
OUT 2 (pin 5): NC contact preset
Output current
Max. 100mA
Switching range adjustment
1-point teach: teach-in button 2 … 7s,
2-point teach: teach-in button 7 … 12s
Changeover
NO/NC
Teach-in button > 12s
Indicators
Yellow LED
OUT1: object detected
Blue LED
OUT2: object detected
Flashing yellow or blue LED
Teach-in
Flashing green and yellow/blue LEDs
Teaching error
Green LED
Object within the scanning range
Mechanical data
Housing
Plastic (PBT)
Active surface
Epoxy resin, glass fiber reinforced
Weight
140g / 170g
Ultrasonic transducer
Piezoceramic
7)
7) The ceramic material of the ultrasonic transducer contains lead zirconium titanate (PZT)
Connection type
M12 connector, 5-pin
Fitting position
Any
Environmental data
Ambient temp. (operation/storage)
-20° … +70°C/-20° … +70°C
Protective circuit
8)
8) 1=short-circuit and overload protection, 2=polarity reversal protection, 3=wire break and inductive protection
1, 2, 3
VDE protection class
III
Degree of protection
IP 67
Standards applied
EN 60947-5-2
Certifications
UL 508, CSA C22.2 No.14-13
6)
9)
9) These proximity switches shall be used with UL Listed Cable assemblies rated 30V, 0.5A min,
in the field installation, or equivalent (categories: CYJV/CYJV7 or PVVA/PVVA7)
Diagrams
HTU330-3500.3/…-M12
0
1000
2000
3000
4000
y1
y2
-400
-200
0
200
400
-300
-100
100
300
Object distance x [mm]
W
idth
y of
th
e so
und
co
ne
[m
m]
Typ. response behavior
(plate 200x200mm)
0
1000
2000
3000
4000
y1
y2
-400
-200
0
200
400
-300
-100
100
300
Object distance x [mm]
W
id
th
y of
th
e so
und
co
ne
[m
m]
Typ. response behavior
(rod Ø 25mm)
HTU330-6000.3/…-M12
Notes
Observe intended use!
This product is not a safety
sensor and is not intended
as personnel protection.
The product may only be put
into operation by competent
persons.
Only use the product in ac
-
cordance with its intended
use.
y1
y2
-600
-400
0
200
-200
400
600
0
2000
4000
6000
Object distance x [mm]
Wi
dt
h y
of t
he
sou
nd
con
e [m
m
]
Typ. response behavior
(plate 200x200mm)
y1
y2
-600
-400
0
200
-200
400
600
0
2000
4000
6000
Object distance x [mm]
W
idth
y o
f th
e so
un
d co
ne
[m
m]
Typ. response behavior
(rod Ø 25mm)
Object distance [mm]
Target (fixed):
plate or rod
Sound cone
= f (
D
,x)
HTU330