Adjusting the switching function (NC/NO) via the teach button

The switching function of the sensor is preset as follows on delivery:

OUT 1: NO contact

OUT 2: NC contact

The output function for each output can be individually switched from NO contact (NO - normally open) to NC contact (NC - nor

-

mally closed) and vice versa. If the switching function is changed, the switching output is changed to the opposite state (toggled).
First activate the previously described teach mode for output OUT 1 or OUT 2.

Changeover of the switching function

1.To change the switching function of the selected output, press the teach button for longer than 12s. 

The current state of the selected output is frozen during the adjustment process.

2.The green and yellow (blue) LEDs flash alternately at 3Hz. 

If the yellow (blue) LED is ON afterwards, the selected output operates as an NO contact.

If the yellow (blue) LED is OFF afterwards, the selected output operates as an NC contact.

HTU330

Summary of Contents for HTU330 Series

Page 1: ... point can be taught NO NC function reversible 2 independent switching outputs PNP or NPN NEW Both outputs can easily be taught using a button NEW Stable plastic design NEW Temperature compensated scanning range 250 3500mm 350 6000mm Accessories available separately Mounting systems Cables with M12 connector KD Dimensioned drawing A Active sensor surface B Teach in button C Indicator diodes DMU330...

Page 2: ... Plastic PBT Active surface Epoxy resin glass fiber reinforced Weight 140g 170g Ultrasonic transducer Piezoceramic 7 7 The ceramic material of the ultrasonic transducer contains lead zirconium titanate PZT Connection type M12 connector 5 pin Fitting position Any Environmental data Ambient temp operation storage 20 70 C 20 70 C Protective circuit 8 8 1 short circuit and overload protection 2 polari...

Page 3: ...connector pin 4 black cable wire OUT1 4 PNP output NO contact preset P PNP output NC contact preset 2 NPN output NO contact preset N NPN output NC contact preset Pin assignment of connector pin 2 white cable wire Analog OUT OUT2 4 PNP output NO contact preset P PNP output NC contact preset 2 NPN output NO contact preset N NPN output NC contact preset C Analog output 4 20mA V Analog output 0 10V Pi...

Page 4: ...LED OFF Green LED ON Distance Hysteresis Switching point Scanning range OUT not active Yellow blue LED OFF Green LED OFF OUT not active Yellow blue LED OFF Green LED OFF Dead zone Sensor OUT not active Yellow blue LED OFF Green LED ON OUT active Yellow blue LED ON Green LED OFF Distance Hysteresis Switching point Scanning range OUT active Yellow blue LED ON Green LED OFF OUT active Yellow blue LED...

Page 5: ...ior with 2 point window teach as a function of the switching function 1 Place object at desired switching distance 1 First place object at desired switching distance for switching point 1 2 To adjust the selected output press the teach button for 2 7s until the yellow LED OUT 1 or blue LED OUT 2 flashes at 3Hz The current state of the selected output is frozen during the adjustment process 2 To ad...

Page 6: ...d the switching output is changed to the opposite state toggled First activate the previously described teach mode for output OUT 1 or OUT 2 Changeover of the switching function 1 To change the switching function of the selected output press the teach button for longer than 12s The current state of the selected output is frozen during the adjustment process 2 The green and yellow blue LEDs flash a...

Page 7: ...gram A synchronization pulse from the control activates synchronous operation The devices work in synchronous operation with a simultaneous transmission pulse The response time of the individual sensors in the network corresponds approximately to that of a single sensor Synchronous operation wiring schematic Timing diagram for synchronous operation Working distance Minimum mounting distance 1 500m...

Page 8: ...ease the button The green yellow and blue LEDs flash alternately and very quickly for a brief time The sensor was reset to the factory setting switching output OUT 1 NO contact 1 switching point at 3500 mm or 6000 mm static 1 point teach switching output OUT 2 NC contact 1 switching point at 3500 mm or 6000 mm static 1 point teach Sensor 2 Sensor 1 Sensor n NOTE Please make certain that the wiring...

Reviews: