PROFINET interface
Leuze electronic GmbH + Co. KG
AMS 348
i
57
TNT
35/7-2
4V
9.7
PROFINET electrical connection
Figure 9.3: PROFINET - Electrical connection
Note!
For connecting BUS IN and BUS OUT, we recommend our ready-made PROFINET cables
(see chapter 11.4.5 "Accessories - Ready-made cables for PROFINET").
To set up a PROFINET network with other participants in a linear topology, the AMS 348
i
provides an additional PROFINET-RT interface. The use of this interface drastically reduces
the cabling requirements, as only the first AMS 348
i
requires a direct connection to the switch,
via which it can communicate with the host. All other AMS 348
i
can be connected in series
to the first AMS 348
i
For the connection of two AMS 348
i
, the "KSS ET
-
M12
-
4A
-
M12
-
4A
-
P7
-
…" ready-made
cables are preferred, see Table 11.4.5 "Accessories - Ready-made cables for PROFI
If you use ready-made cables, note the following:
M12 socket
(D-coded)
M12 socket
(D-coded)
BUS IN (4-pin socket, D-coded)
BUS OUT (4-pin socket, D-coded)
Pin
Name
Comment
Pin
Name
Comment
1
TD+
Transmit Data +
1
TD+
Transmit Data +
2
RD+
Receive Data +
2
RD+
Receive Data +
3
TD-
Transmit Data -
3
TD-
Transmit Data -
4
RD-
Receive Data -
4
RD-
Receive Data -
Thread
FE
Functional earth (housing)
Thread
FE
Functional earth (housing)
BUS IN
TD+ 1
2
3
4
RD+
RD-
TD-
BUS OUT
TD+ 1
2
3
4
RD+
RD-
TD-