Technical Data 
Function 

 

Function indicator 

3 LED, green 

Function type/setting  

Time, continuous 

Adjustment ranges 

0.15 - 3 s, 1.5 - 30 s 

Power circuit 

 

Rated voltage U

N

 

DC 24 V 

Rated power DC 

2.6 W 

Operating voltage range 

0.85 - 1.1 x U

N

 

Galvanic isolation between supply/Control circuits 

No 

 
Control circuits 

Rated output voltage, S11 and S33 against S21 

DC 22 V 

Input current/peak current at S12 and S31/S22 

25 mA / 100 mA 

Input current/peak current at S34 and S35 

40 mA / 100 mA 

Response time (manual start t

A1

/autom. start t

A2

30 ms / 700 ms 

Minimum activation time t

M

 (manual start)  

200 ms 

Recovery time t

W

  

500 ms 

Release time t

R1

 (immediately switching contacts) 

25 ms 

Release time t

R2

 (delayed contacts)  

0.15 s - 3 s ±16% 

1.5 s - 30 s ±16% 

7.5 s - 150 s ±25% 

Synchronous time monitoring t

S

  

< 500 ms 

Permitted test pulse type t

TP

  

< 1 ms 

Max. line resistance per channel 

≤  

(5 + (1.176 x U

B

/U

N

 - 1) x 100) 

 

 
Output circuits 

Enabling current path 13/14 and 23/24 

Normally open contact 

Enabling current path 37/38 

Normally open contact, release-delayed 

Contact type 

Forcibly actuated 

Contact material 

Ag-alloy gold-plated 

Rating switching voltage U

n

 

AC 230 V 

Max. thermal permanent current I

n

 per enabling current path 

6 A 

Max. total current I² all enabling current paths 

5 A² bei +55°C (diagram "Total Current") 

Utilisation category according to EN 60947-5-1 

 

Immediately switching contacts 

Delayed contacts 

AC-15: Ue AC 230 V, Ie 4 A 

DC-13: Ue DC 24 V, Ie 2 A 

AC-15: Ue AC 230 V, Ie 3 A 

DC-13: Ue DC 24 V, Ie 3 A 

Short circuit protection, fuse/circuit breaker. 

6 A gG, fuse integral < 100 A²s 

Conditional short-circuit current according to EN60947-5-1. 

1000 A 

Mechanical service life 

10 

7

 

 
General Data 

Air gap and creepage paths between the circuits  

EN 60664-1 

Rated voltage 

300 V 

Overvoltage category/Rated surge voltage 

III / 4 kV (Basic insulation) 

Pollution degree: inside/outisde 

2 / 3 

Protection class according to EN 60529 case/terminals 

IP 40 / IP 20 

Ambient operating temperature and Storage temperature 

-25 to +55 °C / -25 to +75 °C 

Oscillations, sinusoidal according to EN 60068-2-6 

10 - 55 Hz / 0.35 mm 

Weight 

0.2 kg 

Standards 

EN ISO 13849-1, EN 62061 

Terminals and connection data 

Screw terminals 

Spring-loaded terminals 

Single-core or finely stranded 

1 x 0.2 - 2.5 mm² / 

2 x 0.2 - 1.0 mm² 

2 x 0.2 - 1.5 mm² 

Finely stranded with wire-end ferrule 

1 x 0.25 - 2.5 mm² / 

2 x 0.25 - 1.0 mm² 

2 x 0.25 - 1.5 mm²  

AWG conductor size (only use Cu wires) 

26 - 14 

24 - 16 

Maximum tightening torque 

0.5 to 0.6 Nm (5 - 7 lbf-in) 

--- 

Stripping length 

7 mm 

 

 

Summary of Contents for MSI-SR-LC21DT03 Series

Page 1: ...arte unter Spannung stehende Teile ab 6 Der Einbau der Ger te muss in einem Schaltschrank mit einer Schutzart von min destens IP 54 erfolgen Achtung Eingeschr nkter Ber hrungsschutz Schutzart nach EN...

Page 2: ...ch z B eine maximale Zyklenanzahl von 400 000 0 1 x 30 133 333 Schaltzyklen Jahr Das Betreiben des Ger tes au erhalb der Spezifikation kann zu Funktionsst rungen oder zur Zerst rung des Ger tes f hren...

Page 3: ...allverz gert Kontaktart zwangsgef hrt Kontaktwerkstoff Ag Legierung vergoldet Schaltnennspannung Un AC 230 V max thermischer Dauerstrom In pro Freigabestrompfad 6 A max Summenstrom I aller Freigabestr...

Page 4: ...ed in a cabinet with a protection class of at least IP 54 Caution Limited contact protection Protection type according to EN 60529 Housing terminals IP 40 IP 20 Finger proof acc to EN 50274 Device and...

Page 5: ...plication case Assuming that the B10d value for the maximum load is 400 000 this results in a maximum cycle number of 400 000 0 1 x 30 133 333 switching cycles year Operating the device not within the...

Page 6: ...ted Contact material Ag alloy gold plated Rating switching voltage Un AC 230 V Max thermal permanent current In per enabling current path 6 A Max total current I all enabling current paths 5 A bei 55...

Page 7: ...tez les 5 Couvrez et isolez les pi ces voisines sous tension 6 Le montage des appareils doit tre effectu dans une armoire lectrique avec une classe de protection min IP 54 Attention Protection partiel...

Page 8: ...un nombre maximal de cycles de 400 000 0 1 x 30 133 333 cycles de commutation an L utilisation de l appareil non conforme aux sp cifications peut provoquer des dysfonctionnements ou la destruction de...

Page 9: ...sation au d clenchement Type de contact commande forc e Mat riau du contact Alliage Ag dor Tension nominale de commutation Un AC 230 V Courant thermique permanent max In par trajet de courant de valid...

Page 10: ...ne 7 Gli apparecchi devono essere installati in un armadio elettrico con grado di prote zione minimo pari a IP 54 Attenzione Protezione da contatto limitata Grado di protezione secondo EN 60529 Allogg...

Page 11: ...000 0 1 x 30 133 333 cicli di commutazione anno L utilizzo dell apparecchio al di fuori delle specifiche pu provocare anomalie di funzionamento o danni irreparabili all apparecchio In caso di avvio m...

Page 12: ...rzata Materiale contatti Lega Ag placcata oro Tensione nominale di commutazione Un AC 230 V Corrente permanente max In per circuito di abilitazione 6 A Corrente cumulativa max I di tutti i circuiti di...

Page 13: ...e distribuci n con una clase de protecci n IP 54 como m nimo Atenci n Protecci n contra contacto limitada Clase de protecci n seg n EN 60529 Caja bornes IP 40 IP 20 A prueba de contacto involuntario c...

Page 14: ...33 333 ciclos de conmutaci n a o La utilizaci n del aparato m s all de las especificaciones puede conllevar fallos en el funcionamiento o da os irreparables en el aparato El pulsador de reinicio no se...

Page 15: ...conexi n Tipo de contactos de accionamiento forzado Material de los contactos Aleaci n de plata dorados Tensi n nominal de conmutaci n Un AC 230 V Corriente t rmica constante m x In por l nea de conta...

Page 16: ...al start and cross monitoring Arr t d urgence 2 canaux d tection de courts circuits avec d marrage manuel 2 1 RESET mit Reset Taster berwachung S34 RESET with reset button monitoring S34 RESET avec su...

Page 17: ...ia bicanal con arranque manual y detecci n de cortocircuitos transver sales 2 1 RESET con controllo del pulsante di reset S34 REINICIO con control de pulsador de reinicio S34 2 2 Ponte Puente 3 Porta...

Page 18: ...orgungsspannung Power Supply Tension d alimentation S12 Kanal 1 Channel 1 Canal 1 S31 S22 Kanal 2 Channel 2 Canal 2 S34 Reset fallende Flanke Reset falling edge Reset front descendant S35 Reset steige...

Page 19: ...K3 K4 A1 A2 Tensione di alimentazione Tensi n de alimentaci n S12 Canale 1 Canal 1 S31 S22 Canale 2 Canal 2 S34 Reset fronte di discesa Reinicio flanco descendente S35 Reset fronte di salita Reinicio...

Page 20: ...DIN rail in direction of arrow until it locks into place Appuyez le relais l g rement contre le rail DIN en direction de la fl che Demontage Disassembly D montage 3 3 3 Relais in Pfeilrichtung herunt...

Page 21: ...scattare il rel sulla barra DIN Encaje el rel en el carril DIN presion ndolo ligeramente en el sentido de la flecha Smontaggio Desmontaje 3 3 Spingere in basso il rel in direzione della freccia Empuje...

Page 22: ...Leuze electronic GmbH Co KG In der Braike 1 D 73277 Owen We reserve the right to make changes info leuze de www leuze com Tel 49 0 7021 573 0 01 2018 50134621 01 22 23...

Page 23: ...Leuze electronic GmbH Co KG In der Braike 1 D 73277 Owen We reserve the right to make changes info leuze de www leuze com Tel 49 0 7021 573 0 01 2018 50134621 01 23 23...

Reviews: