Modes
Leuze electronic
MA 258
i
63
TNT
35/7-2
4
V
Examples for the activation of a Leuze device
In the data part (starting at byte 2) of the telegram to the gateway, a "+" (ASCII) is sent for
activation.
This means that the hex value "2B" (corresponds to a "+") is to be entered in control or output
byte 2. To deactivate the reading gate, a "2D" (hex) must be used instead (corresponds to
a "-" ASCII).
7
6
5
4
3
2
1
0
ND
Address 4
Address 3
Address 2
Address 1
Address 0
Broadcast
Command
mode
Control byte 0
CTB
SFB
R-ACK
Control byte 1
Data byte 1
Data
Data byte 2
…
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
Output byte 0
0
0
0
0
0
0
0
0
Output byte 1
0
0
0
0
0
0
B
2
Output byte 2
0
0
0
0
0
0
0
0
Output byte 3