Electrical connection
Leuze electronic
Technical description LES
47
TNT
35/7-2
4
V
6.3
Connecting
6.3.1
Connection X1 - logic and power
Attention!
All cables must be shielded!
Preferably, please use the ready-made cables "K-D M12A-8P…", see chapter 15.2.2.
Figure 6.6:
Internal wiring at X1
Power supply
For power supply specifications please refer to chapter 14.
Activation input InAct
The activation input is used to switch the laser on and off via the process control. The sensor
stops outputting data and does not respond to trigger commands or the trigger input. The
equivalent circuit of the inputs at X1 is shown in figure 6.6.
Trigger input InTrig
The trigger input is used for synchronizing the measurement with the process and for
synchronizing cascaded sensors. Detailed information on this topic can be found in chapter
4.2.3 and chapter 4.2.4. The internal equivalent circuit is shown in figure 6.6.
X1 (8-pin plug, A-coded)
Pin
Name
Core color
Remark
1
VIN
WH
+24VDC supply voltage
2
InAct
BN
Activation input
3
GND
GN
Ground
4
OutReady
YE
"Ready" output
5
InTrig
GY
Trigger input
6
OutCas
PK
Cascading output
7
BU
Do not connect
8
RD
Do not connect
Table 6.3:
Pin assignment X1
X1
VIN
InAct
InTrig
OutReady
OutCas
GND
7
8
M 12 plug
(A-coded)
X1-2/5
10k
10k
X1-3
X1-1
X1-4/6
GND
18 - 30 VDC
100 mA (max. 250 mA)
X1-3
Inputs