Display and control panel
56
Technical description LES
Leuze electronic
7.2
Menu description
7.2.1
Structure
Level 1
Level 2
Level 3
Explanation / Notes
Default
Settings
Menu Exit
Set Act. Insp. Task
00: Task 0
Here you select the active task 00 to
15.
Set Act. Insp. Task
00: Task 0
Set Act. Insp. Task
15: Task 15
Set Act. Insp. Task
00: Task 0
Ext. Task Selection
1
Ext. Task Selection
1
If you press
here, external task
changeover will be activated. Task
changeover via the display / menu is
NOT
possible.
Ext. Task Selection
0
If you press
here, task changeover
will be activated via the display/menu.
External task changeover is
NOT
possible.
Ext. Task Selection
1
Display
On
Display
On
Always on with maximum brightness
Display
Off
Off; is switched back on after
keyboard actuation
Display
Auto
Display set to full brightness after
keyboard actuation for approx. 1min.,
dimmed thereafter
X
Display
On
Data Output
Ethernet
Prescaler Value
001
Attention:
the value is permanently
set to 1 and cannot be changed.
Data Output
Ethernet
Ethernet
Factory Settings
IP Address
192.168.060.003
Here you can set the IP address of the
LES.
Table 7.2:
Menu structure