Interfaces – Communication
Leuze electronic
DCR 202i
51
Manual definition of the reference code
Teach-in
Acknowledgment yyy zzzzzz
yyy
Read quality in [%].
zzzzzz
Code information
Command
JP
Command
RS
Description
This command can be used to define a new reference code in the code reader by
means of direct input via the serial interface or the Ethernet interface.
Parameter
RSyvxxzzzzzzzz
y, v, x and z are placeholders (variables) for the actual input.
y
Def. reference code no.
1
(Code 1)
v
Storage location for reference code:
3
RAM only
xx
Defined code type (see command 'CA')
z
Defined code information (1 … 244 characters)
Acknowledgment RS=x
x
Status
00
Valid 'Rx' command
01
Invalid command
02
Insufficient memory for reference code
03
Reference code has not been saved
04
Reference code invalid
Example
Entry = RS103211032010
Code 1 (1), RAM+EEPROM (0), DataMatrix ECC 200 (32), code information
Command
RT
Description
This command enables a reference code to be defined quickly by reading an exam
-
ple label.
Parameter
RTy
y
Function
1
Defines reference code 1