Mounting
Leuze electronic
DCR 202i
25
6.2.1 Mounting with M4 fastening screws
Mount the device on the system with M4 fastening screws (not included in delivery contents).
Max. tightening torque of the fastening screws: 1.4 Nm
Location and thread depth of the mounting thread: see figure 14.1
6.2.2 Mounting with the BTU 320M-D12 mounting system
Mounting with a BTU 320M-D12 mounting system is intended for 12-mm rod mounting. For ordering infor
-
mation, see chapter 15.5.
Mount the mounting system on the rod with the clamp profile (system-side).
Mount the device to the mounting system with M4 fastening screws.
Max. tightening torque of the fastening screws: 1.4 Nm
Location and thread depth of the mounting thread: see figure 14.1
6.2.3 Mounting with the BT 320M mounting bracket
Mounting with a BT 320M mounting bracket is intended for wall mounting. For ordering information, see
Mount the mounting bracket on the system side with M4 fastening screws (included in delivery con
-
tents).
Mount the device to the mounting bracket with M4 fastening screws.
Max. tightening torque of the fastening screws: 1.4 Nm
Location and thread depth of the mounting thread: see figure 14.1
6.3
Replace housing hood
In individual cases, you can exchange the housing hood of the code reader, e.g., if the protective screen
is scratched or if changed operating conditions necessitate a housing hood with polarization filter. For
ordering information, see chapter 15.3.
Loosen the four fastening screws of the housing hood.
First tip the housing hood downward and away from the housing base.
Then lift the housing hood up and off of the housing base.
Then mount the new housing hood in the reverse order.
The tightening torque of the fastening screws is 0.25 Nm.
NOTICE
Only replace the housing hood while the device is in a de-energized state!
Only replace the housing hood if
no voltage
is being applied to the device.
Disconnect the device from the voltage supply before replacing the device hood.
NOTICE
Check the seal before mounting!
Check the seal on the base of the code reader housing for cleanliness before mounting the new hous
-
ing hood.
NOTICE
Clean the new housing hood before mounting!
Clean the new housing hood with a soft cloth before mounting.