DeviceNet interface
Leuze electronic GmbH + Co. KG
AMS 355
i
77
TNT
35/7-2
4V
9.6.6.6 Function assignment of hardware outputs
Instance 1, attribute 3 (PIN 2/M12 Power)
Instance 2, attribute 3 (PIN 4/M12 Power)
The attribute defines which event triggers activation of the output. The individual functions
are OR-linked.
For instance 1 attribute 3, the default 192
d
/ 00 C0
h
/ 0000 0000 1100 0000
b
is specified. This
means that an edge change, as defined in attribute 2, takes place at the output (PIN 2) if the
ERR or PLB message occurs.
For instance 2 attribute 3, the default 56
d
/ 00 38
h
/ 0000 0000 0011 1000
b
is specified. This
means that an edge change, as defined in attribute 2, takes place at the output (PIN 4) if the
LSR or TMP or ATT message occurs.
9.6.6.7 Output function state
Instance 1, attribute 5 (PIN 2/M12 Power)
Instance 2, attribute 5 (PIN 4/M12 Power)
0 = Output function is not active. No event from attribute 3 is active.
1 = Output function is active. At least one event from attribute 3 is activated.
9.6.6.8 Activation of output (dynamic output)
Instance 1, attribute 6 (PIN 2/M12 Power)
Instance 2, attribute 6 (PIN 4/M12 Power)
With the dynamic output, the hardware outputs (PIN 2/PIN 4) can be set using the control
software.
Actuation takes place via bit 8.
0 = Dynamic output active
1 = The hardware output(s) are set as defined in attribute 2
Dynamic setting of the outputs is performed via 256
d
(256 = without taking the status
messages bit 7 to bit 2 into consideration).
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Hardware
(ERR)
Plausibility
(PLB)
Laser
(LSR)
Tempera
-
ture
(TMP)
Intensity
(ATT)
Velocity limit
value vio
-
lated
Reserved
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Bit 8
Reserved
Dynamic
output