8.3.2
Parameter menu
Parameter handling submenu
The following functions can be called up in the
Parameter handling
submenu:
• Lock and enable parameter entry
• Set up a password
• Reset the AMS 355
i
to the default settings
Additional important information on parameter handling can be found at the end of the
chapter.
DeviceNet submenu
Table 8.1:
Parameter handling submenu
Level 3
Level 4
Level 5
Selection/configuration option
Description
Standard
Parameter
enable
ON/OFF
The standard setting (
OFF
) prevents unintended parameter
changes.
With parameter enable activated (
ON
), the display is inverted.
In this state, it is possible to change parameters manually.
OFF
Password
Activate
password
ON/OFF
To enter a password, parameter enable must be activated.
If a password is assigned, changes to the AMS 355
i
can only
be made after the password is entered.
The master password 2301 overrides the individually set
password.
OFF
Password
entry
For setting a four-digit numerical password.
Parameters to
default
By pressing the enter button
after selecting
Parameters to default
, all parameters are reset to their standard
settings without any further security prompts.
In this case, English is selected as the display language.
Tabelle 8.2: DeviceNet submenu
Level 3
Level 4
Level 5
Selection/configuration option
Description
Standard
Activation
ON/OFF
ON
Node ID
Entry of the device address.
63
Baud rate
125kbit/s / 250kbit/s / 500kbit/s
Selection of the serial communication baud rate. The baud
rate specifies the velocity of the data transmission. It must be
identical on transmitter and receiver side in order to enable
communication.
125kbit/s