DeviceNet interface
76
AMS 355
i
Leuze electronic GmbH + Co. KG
9.6.6.3 Function assignment of inputs
Instance 1, attribute 4 (PIN 2/M12 Power)
Instance 2, attribute 4 (PIN 4/M12 Power)
Attribute 4 determines which function is to be triggered in the AMS 355
i
when the input is set.
Bit 0 = Preset teach
The switching input reacts to the edge set in attribute 2. The preset value is adopted at the
position at which the switching input detects an edge change as defined in attribute 2.
Bit 1 = Laser ON/OFF
The switching input reacts to the edge set in attribute 2. The laser is switched OFF if the
switching input detects an edge change as described in attribute 2. If an opposing edge is
detected at the switching input, the laser is switched ON again.
9.6.6.4 Input function state
Instance 1, attribute 5 (PIN 2/M12 Power)
Instance 2, attribute 5 (PIN 4/M12 Power)
0 = Input function is not active. Neither Laser ON/OFF nor Preset teach is active.
1 =Input function is active. Laser ON/OFF or Preset teach or both has been activated.
Attribute description for cases where attribute 1 in instance 1 or 2 is selected as a switching
output.
9.6.6.5 Activation for outputs
Instance 1, attribute 2 (PIN 2/M12 Power)
Instance 2, attribute 2 (PIN 4/M12 Power)
The attribute defines the level of the output at which the "Output" event occurs.
0 = from logical 1 to logical 0 if the "output" event occurs (see Attribute 3)
1 = from logical 0 to logical 1 if the "output" event occurs (see Attribute 3)
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
-
-
-
-
-
-
Laser ON/
OFF
Preset teach