![Leuze electronic AMS 348i SSI Original Operating Instructions Download Page 86](http://html.mh-extra.com/html/leuze-electronic/ams-348i-ssi/ams-348i-ssi_original-operating-instructions_1883971086.webp)
PROFINET interface
Leuze electronic
AMS 348
i
SSI
83
TNT
35/7-2
4
V
Output data
Lower posi-
tion limit
value 2
Signals that the value is less than lower
limit value 2.
0.6
Bit
0: OK
1: Value less than limit
–
–
–
Upper posi-
tion limit
value 2
Signals that the value is greater than
upper limit value 2.
0.7
Bit
0: OK
1: Value greater than limit
–
–
–
Input data length: 2 bytes
l
m
Output data
Description
Rel.
addr.
Data
type
Value
Default
Unit
CR to
module
Metr.
Inch
Laser
Laser control.
0.0
Bit
0: Laser ON
1: Laser OFF
–
–
–
Output data length: 2 bytes
n