![Leuze electronic AMS 348i SSI Original Operating Instructions Download Page 17](http://html.mh-extra.com/html/leuze-electronic/ams-348i-ssi/ams-348i-ssi_original-operating-instructions_1883971017.webp)
Specifications
14
AMS 348
i
SSI
Leuze electronic
4
Specifications
4.1
Specifications of the laser measurement system
4.1.1
General specifications AMS 348
i
SSI
Measurement data
AMS 348
i
40 (H)
SSI
AMS 348
i
120 (H)
SSI
AMS 348
i
200 (H)
SSI
AMS 348
i
300 (H)
SSI
Measurement range
0.2 … 40m
0.2 … 120m
0.2 … 200m
0.2 … 300m
Accuracy
± 2mm
± 2mm
± 3mm
± 5mm
Consistency
1)
0.3mm
0.5mm
0.7mm
1.0mm
Light spot diameter
≤
40mm
≤
100mm
≤
150mm
≤
225mm
Output time
1.7ms
Response time
14ms
Basis for contouring error calculation
7ms
Resolution
adjustable, see chapter of the individual interfaces
Temperature drift
≤
0.1mm/K
Ambient temperature sensitivity
1ppm/K
Air pressure sensitivity
0.3ppm/hPa
Traverse rate
≤
10m/s
Electrical data
Supply voltage Vin
2)
18 … 30VDC
Current consumption
without device heating:
≤
250mA / 24VDC
with device heating:
≤
500mA / 24VDC
Optical data
Transmitter
laser diode, red light
Laser class
2 in accordance with IEC 60825-1:2007, CDRH
Wavelength
655nm
Impulse duration
≤
18μs
Max. output power (peak)
≤
4mW
PROFINET interface
Interface type
PROFINET-RT with integrated switch
for BUS IN and BUS OUT
Protocol
PROFINET-RT communication
Conformance Class
B
SSI interface
Interface type
SSI interface
SSI clock rate
50kHz … 800kHz
Data format
Operating and display elements
Keyboard
4 buttons
Display
monochromatic graphical display, 128 x 64 pixels
LED
4 LEDs, 2 of which are used to display the PROFINET connection