![Leuze electronic AMS 348i SSI Original Operating Instructions Download Page 42](http://html.mh-extra.com/html/leuze-electronic/ams-348i-ssi/ams-348i-ssi_original-operating-instructions_1883971042.webp)
Electrical connection
Leuze electronic
AMS 348
i
SSI
39
TNT
35/7-2
4
V
7.4
PROFINET BUS OUT
Table 7.3:
Pin assignment BUS OUT
7.5
SSI
Table 7.4:
SSI pin assignment
BUS OUT (4-pin socket, D-coded)
Pin
Name
Remark
1
TD+
Transmit Data +
2
RD+
Receive Data +
3
TD-
Transmit Data -
4
RD-
Receive Data -
Thread
FE
Functional earth (housing)
BUS OUT
TD+ 1
2
3
4
RD+
RD-
TD-
M12 socket
(D-coded)
SSI (5-pin plug, B-coded)
Pin
Name
Remark
1
DATA+
+
Data line SSI (output)
2
DATA-
-
Data line SSI (output)
3
CLK+
+
Clock line SSI
(input electrically insulated)
4
CLK-
-
Clock line SSI
(input electrically insulated)
5
FE
Functional earth
Thread
FE
Functional earth (housing)
SSI
CLK+ 3
2
1
4
FE
DATA-
CLK-
DATA+
5
M12 connector
(B-coded)