SSI
Leuze electronic
AMS 348
i
SSI
103
TNT
35/7-2
4
V
10.1.1
SSI sequence diagram
Figure 10.1: SSI data transmission sequence diagram
Notice!
In the default setting the
LSB
bit is the error bit.
Attention!
Significance of the error bit
:
By default a 25th error bit (LSB) is appended to the 24-bit measurement value.
The error bit is not included in the Gray coding of the measurement value.
The error bit is 1 = active, 0 = not active.
Notice!
The data can be read out with a clock rate between 80kHz and 800kHz.
Attention!
Updating the measurement values on the SSI interface of the
AMS 348
i
SSI:
The measurement value on the SSI interface of the AMS 348
i
SSI is updated every 1.7ms
independent of the clock frequency.
Clock sequence
Complete transmission cycle