PROFINET interface
Leuze electronic
AMS 348
i
SSI
97
TNT
35/7-2
4
V
9.9.3.17 Module 17: SSI interface
PROFINET module identifier
Module ID
1017
Submodule-ID 1
Description
The module defines the parameters for the SSI interface.
Attention!
The SSI interface can only represent positive distance values. If negative output values
are ascertained due to the offset or count direction, a zero value is output at the SSI
interface! In the event of a number overflow, all data bits are set to "1".
The
unit
,
offset
and
count direction
parameters of module 1 also apply to the SSI interface.
Notice!
If the SSI interface is not configured via module 17 (SSI interface) in PROFINET oper-
ation, the SSI interface is operated with the default parameters.
If the SSI interface is operated without PROFINET (PROFINET OFF/SSI ON), configuration
is performed via the display.