Commissioning
820XBA1097
5-3
5.2.2
Factory setting of the most important drive
parameters
Setting
Code
Factory setting
Adaption to
the
application
Operating mode
C001
-0-
Setpoint selection via terminal 8
Control via terminals
Parameter setting via 8201BB
See code
table,
chapter 7.2
Terminal configuration
C007
-0-
E4
E3
E2
E1
CW/CCWDC injection brake JOG1/2/3
See code
table,
chapter 7.2
Machine data
Chapter 5.3 ff.
Speed range
Min. field frequency
C010
0.0 Hz
Chapter 5.3.1
Max. field
frequency
C011
50.0 Hz
Acceleration
and
deceleration
Acceleration time
C012
5.0 s
Chapter 5.3.2
and
deceleration
times
Deceleration time
C013
5.0 s
Current limit
values
Motor mode
C022
150 %
Chapter 5.3.3
values
Generator mode
C023
80 %
Drive performance
Chapter 5.4 ff.
Current,
torque,
power
Operating mode
C014
-0-
Linear characteristic V
f
d
with auto
boost
V/f
characteristic
control
power
characteristic V/f rated frequency
C015
50.0 Hz
control
-
with auto
boost, see
chapter
V
min
setting
C016
type
dependent
chapter
5.4.1.1
-
with V
min
boost, see
Slip compensation
C021
0 %
with V
min
boost, see
chapter
5.4.1.2