![Lenze EVF8201-E Operating Instructions Manual Download Page 15](http://html1.mh-extra.com/html/lenze/evf8201-e/evf8201-e_operating-instructions-manual_1882342015.webp)
Technical Data
820XBA1097
3-3
150 % overload
8204
8203
8202
8201
Type
EVF8204-E
EVF8203-E
EVF8202-E
EVF8201-E
Order no.
Variant ”reduced assembly
depth”
8202-V002
Type
Variant ”reduced assembly
depth”
EVF8202-E- V002
Order no.
Power derating
[%/K]
[%/m]
40
C < T
amb
< 50
C: 2,5%/K
1000 m a.m.s.l.
h
$
4000 m a.m.s.l.: 5%/1000 m
Field
frequency
Resolution
Absolute
0.05 Hz
Field
frequency
Digital setpoint
selection
Accuracy
á
0.05 Hz
Analog setpoint
selection
Linearity
á
0.5 % (max. selected signal level, 5V or 10V)
Analog setpoint
selection
Temperature
sensitivity
0
¤
40
C: + 0.4 %
Offset
á
0.3 %
Weight
m [kg]
1.0
1.3
Variant 1.0
2.2
2.2
1)
This power can be additionally obtained when operating a matching motor
2)
The currents apply to a periodical load cycle with 1 minute overcurrent with the current mentioned here
and 2 minutes base load with 75% I
Nrated
.
3)
With mains choke/mains filter: max. output voltage = approx. 96 % of the mains voltage
4)
Observe the N-conduction load when having a symmetrical mains distribution!
(See electrical installation)
*
Chopper frequency of the inverter
All manuals and user guides at all-guides.com