Lenze · Inverter Drive 8400 motec (PROFINET® option) · DMS 5.0 EN · 02/2019 · TD23
85
13
Parameter reference
13.2
Parameters relevant for PROFINET communication
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13901
C13902
C13910
C13911
C13912
C13913
Parameter | Name:
C13901 | Firmware Compilation Date
Data type: VISIBLE_STRING
Index: 10674
d
= 29B2
h
The code contains a string with a length of 20 characters. The software creation date ("MMM DD YYYY") and time
("hh:mm:ss") are displayed (e.g. "Mar 21 2005 12:31:21").
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C13902 | Firmware Version
Data type: VISIBLE_STRING
Index: 10673
d
= 29B1
h
The code contains a string with a length of 11 characters. The identification code is displayed (e.g. "01.00.00.00").
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C13910 | I&M1 system designation
Data type: VISIBLE_STRING
Index: 10665
d
= 29A9
h
Input/output of the I&M1 plant identification code
• The Lenze setting shows an empty string.
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C13911 | I&M1 installation site
Data type: VISIBLE_STRING
Index: 10664
d
= 29A8
h
Input/output of the I&M1 location identification code
• The Lenze setting shows an empty string.
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C13912 | I&M2 installation date
Data type: VISIBLE_STRING
Index: 10663
d
= 29A7
h
Input/output of the I&M2 date of installation
• The Lenze setting shows an empty string.
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C13913 | I&M3 additional information
Data type: VISIBLE_STRING
Index: 10662
d
= 29A6
h
Input/output if the I&M3 additional information
• The Lenze setting shows an empty string.
Subcodes
Lenze setting
Info
C13913/1
I&M3 additional information
C13913/2
I&M3 additional information
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM