Implemented CIP™ objects
General CIP objects
119
Lenze · Decentralised frequency inverter 8400 motec (EtherNet/IP™ option) · EDS84DMOTEIP EN 2.0 - 10/2013
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Data mapping of the input assemblies
Supported service codes
Data component
[Bits 0 ... 7]
Class
Instance
Number
Attribute
Name
Number
Name
Number
Faulted [Bit 0]
Control
Supervisor
0x29
1
Faulted
10
Warning [Bit 1]
Control
Supervisor
0x29
1
Warning
11
Running1 (Fwd) [Bit 2]
Control
Supervisor
0x29
1
Running1
7
Running2 (Rev) [Bit 3]
Control
Supervisor
0x29
1
Running2
8
Ready [Bit 4]
Control
Supervisor
0x29
1
Ready
9
CtrlFromNet [Bit 5]
Control
Supervisor
0x29
1
CtrlFromNet
15
RefFromNet [Bit 6]
AC Drive
0x2A
1
RefFromNet
29
At Reference [Bit 7]
AC Drive
0x2A
1
AtReference
3
Drive State [Bits 0 ... 7]
Control
Supervisor
0x29
1
State
6
Speed Actual [Bits 0 ... 7]
AC Drive
0x2A
1
SpeedActual
7
Torque Actual [Bits 0 ... 7]
AC Drive
0x2A
1
TorqueActual
11
Custom Input [Bits 0 ... 7]
Service code
[hex]
Name
Description
0x0E
Get_Attribute_Single
Outputs the value of a certain attribute.
0x10
Set_Attribute_Single
Changes the value of a certain attribute.